English
Language : 

MPO-40D Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Open Frame AC-DC Power Supplies
MPO-40D Series
Dual Output, 40W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 40W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• Dual Outputs
• Universal 90-264 AC Input
Input Voltage Range
Input Frequency
Universal 90
127
47
264
VAC
373
VDC
63
Hz
• EN 60950 Approved (UL)
• Compact 2 x 4 In Package
• Wide Operating Temp Range
Input Filter
Input Current
Inrush Current
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
29.0
Cold Start, 230 VAC
50.0
A Pk
• Meets EN 55022 B
• >200 kHour MTBF
Safety Ground Leakage Current
Output
Parameter
264 VAC
3.5
Conditions
Min. Typ. Max.
mA
Units
Output Voltage/Current
See Model Selection Guide
Output Voltage Tolerance, See Note 1
Output 1
±3.0
Output 2
±5.0
%
Line Regulation, See Note 2
Output 1
±1.0
Output 2
±2.0
%
Load Regulation, See Note 3
Output 1
±3.0
Output 2
±4.0
%
Ripple & Noise (20 MHz), See Note 4
See Model Selection Guide
Hold-Up Time
115 VAC
8
230 VAC
20
mSec
Temperature Coefficient
±0.05
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Over Voltage Protection
130
%
Overload Protection
See Note 3
150
%
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Resistance
500 VDC
1,000
M⍀
Isolation Capacitance
2,200
pF
EMI/RFI
Conducted
EN 55022; EN 61000-3-2, -3
Electrostatic Discharge (ESD)
IEC/EN 61000-4-2, -6, -8, -11
EMC Compliance
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-3
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Switching Frequency
Fixed
66
kHz
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min. Typ. Max.
Ambient 0 +25 +45
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
93
Units
°C
°C
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Size
Weight
Reliability Specifications
Parameter
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.99 Oz (0.170 kg)
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 200
kHours
Safety Standards
UL 60950, EN 60950
Vibration
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com