English
Language : 

MPO-25S Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Single Output, 25W Compact, Open Frame AC/DC Power Supplies
MPO-25S Series
Single Output, 25W
Compact, Open Frame
AC/DC Power Supplies
Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 25W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• Universal 90-264 AC Input
• EN 60950 Compliant
Input Voltage Range
Input Frequency
Universal 90
127
47
264
VAC
370
VDC
63
Hz
• Low Leakage Current
Input Current
See Model Selection Guide
• Nine Single Output Models
• Meets EN55022
• >500 kHour MTBF
Inrush Current
Safety Ground Leakage Current
Cold Start, 115 VAC
20.0
Cold Start, 230 VAC
36.0
115 VAC
0.35
240 VAC
0.5
A Pk
mA
• Only 4.2” x 2.4” x 1.1”
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Adjustment
See Model Selection Guide
Output Voltage Tolerance, See Note 1
See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2
See Model Selection Guide
Hold-Up Time
115 VAC
20
230 VAC
100
mSec
Set-Up Time
115/230 VAC
200
mSec
Rise Time
RoHS Compliant Temperature Coefficient
115 VAC
230 VAC
30
20
±0.02
mSec
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Over Voltage Protection
See Note 3 115
135
%
Overload Protection
See Note 4 105
%
Over Temperature
See Note 5
U1 >135 °C
General
Parameter
Conditions
Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage
Input to Ground 1,500
VAC
Output to Ground 500
Isolation resistance
500 VDC
100
MΩ
EMI/RFI
Conducted
EN 55022; EN 61000-3-2, -3
MicroPower Direct
Electrostatic Discharge (ESD)
IEC/EN 61000-4-2, -6, -8, -11
292 Page Street
Suite D
Stoughton, MA 02072
USA
EMC Compliance
Switching Frequency
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
100
kHz
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Conditions
Min. Typ. Max.
Ambient -10 +25 +60
-20
+85
Free Air Convection (See Derating Curve)
Units
°C
°C
Humidity
RH, Non-condensing
95
%
Physical
Size
4.2 x 2.4 x 1.1 Inches (107.0 x 67.0 x 28.0 mm)
Weight
4.9 Oz (0.14 kg)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
IEN 60950, IEC 60950
Vibration
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis