English
Language : 

MPM-60PB Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-60PB Series
MPM-60PB Series
Single Output, 60W
Compact “Power Brick”
AC/DC Power Supplies
Key Features:
• 60W Output Power
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• High Power Density Case Parameter
Conditions
Min. Typ. Max. Units
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• -40°C to + 70°C Operation
Input Voltage Range
Input Frequency
Input Current
85
265
100
370
47
63
See Model Selection Guide
VAC
VDC
Hz
• Meets EN 55022 B
• 4,000 VAC I/O Isolation
• >130 kHour MTBF
Inrush Current
Leakage Current
EMI
115 VAC
30.0
230 VAC
50.0
0.5
Meets CISPR Pub. 22/FCC Class B
A Pk
mA
EMC
Meets EN 55024
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
±2.0
%
Output Voltage Adjustment
±10.0
%
Line Regulation
VIN = Min to Max
±1.0
%
Load Regulation
IO = 5% to 100%
±1.0
%
Ripple (20 MHz), See Note 1
<±0.2% Vout + 40 mV mVP-P
Noise, See Note 1
<±0.5% Vout + 50 mV mVP-P
Hold-Up Time
115 VAC
10
230 VAC
60
mSec
Temperature Coefficient
±0.02
%/°C
Over Voltage Protection
Zener Diode Clamp
120
% of VO
Short Circuit Protection, See Note 2
Continuous (Autorecovery)
Overload Protection
150
% of IO
General
Parameter
Conditions
Min. Typ. Max. Units
Input to Output 4,000
Isolation Voltage
Input to FG 1,500
VAC
Output to FG 500
Isolation Resistance
500 VDC 100
M⍀
EMI/RFI
Conducted
EN 55022 Level B
Electrostatic Discharge (ESD)
EN 61000-4-2 Level B
EMC Compliance
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
Surge
EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
100
kHz
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min. Typ. Max.
Ambient -40 +25 +70
-50
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Units
°C
°C
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Reliability Specifications
4.30 x 2.30 x 1.18 Inches (109.0 x 58.5 x 30.0 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
10.92 Oz (310g)
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 130
kHours
Safety Standards
UL 60950, EN 60950
Safety Approvals
UL, cUL; File No. E245422
www.micropowerdirect.com