English
Language : 

MPM-40SE Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-40E Series
MPM-40E Series
Low Cost, Encapsulated
Single Output, 40W
AC/DC Power Supplies
Key Features:
• 40W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Meets EN 55022 Class B
• >200 kHour MTBF
• Low Cost
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
85
264
VAC
120
370
VDC
Input Frequency
47
440
Hz
Input Current
See Model Selection Guide
Inrush Current
115 VAC
30.0
230 VAC
50.0
A Pk
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Standby Power
0.5
W
Output Voltage Accuracy
±2.0
%
Line Regulation
VIN = Min to Max
±0.5
%
Load Regulation
See Note 2
±1.0
%
Ripple & Noise (20 MHz)
50 100
mV P-P
Hold-Up Time
115 VAC
15
230 VAC
80
mSec
Temperature Coefficient
±0.02
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Over Voltage Protection
Zener Diode Clamp
Overload Protection
Autorecovery 110
%W
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Sec 3,000
VAC
Isolation Resistance
500 VDC 100
M
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
EN 55022
Class B
Conducted Emissions
EN 55022
Class B
ESD
EN 61000-4-2 Criteria B; ±8 kV Air/±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Criteria B; ±2 kV
Surge
See Note 4 EN 61000-4-5
Criteria B; ±1 kV/ ±2 kV
CS
EN 61000-4-6
Criteria A; 10 Vrms
PFMF
EN 61000-4-8
Criteria A; 10A/m
Voltage Dips
EN 61000-4-11
Criteria B; 95% 5000 mS
Switching Frequency
65
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +70
°C
Operating Temperature Range
Case
+90
°C
Storage Temperature Range
-40
+85
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
95
%
Physical
Case Size
3.50 x 2.50 x 0.984 Inches (89.0 x 63.5 x 25.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
8.8 Oz (250g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 200
kHours
Safety Standards
EN 60950
Safety Class
IEC 61140 Class II
www.micropowerdirect.com