English
Language : 

MPM-30IS_14 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-30IS Series
MPM-30IS Series
Board Mount, 30W
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features:
• 30W Output Power
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Single, Dual & Triple Outputs
• Meets EN 55022 B
• >250 kHour MTBF
Chassis Mount Models
& DIN Rail Mount
Option Available!
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
85
265
VAC
Input Frequency
47
440
Hz
Input Current
See Model Selection Guide
Inrush Current
115 VAC
20.0
230 VAC
40.0
A Pk
EMI
Meets CISPR Pub. 22/FCC Class B
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy, Note 1
±1.0 ±2.0
%
Line Regulation
VIN = Min to Max
±0.2 ±1.0
%
Load Regulation, Single Output
IO = Min to Max
±0.5 ±1.0
%
Load Regulation, Dual Output
IO = Min to Max
±2.5 ±5.0
%
Load Regulation, Triple Output - Primary
IO = Min to Max
±2.5 ±5.0
%
Load Regulation, Triple Output - Aux.
IO = Min to Max
±4.0
%
Ripple & Noise (20 MHz)
3.3 & 5.0 VDC Output
All Other Outputs
1.5
1.0
1.8
1.3
%VP-P of VO
Hold-Up Time
115 VAC, 60 Hz
20
mSec
Temperature Coefficient
±0.02
%/°C
Over Voltage Protection
Zener Diode Clamp
120
% of VO
Short Circuit Protection, Note 4
Continuous (Autorecovery)
Overload Protection, Note 5
Typ. 120% to 180% of Output Power
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Test Voltage
Input to Output, Flash Tested For 60S 4,700
VAC
Isolation Resistance
500 VDC 100
M⍀
EMI/RFI
Conducted
EN 55022 Level B
Electrostatic Discharge (ESD)
EN 61000-4-2 Level B
EMC Compliance
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
Surge
EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -25 +25 +71
°C
Storage Temperature Range
-40
+85
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
95
%
Physical
Case Size
3.50 x 2.50 x 0.85 Inches (88.9 x 63.5 x 21.5 mm)
Case Material
Non-Conductive Plastic& Fiberglass (UL94-V0)
Weight
6.23 Oz (177g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 250
kHours
Safety Standards
UL 60950, EN 60950
Safety Approvals
UL, cUL; File No. E245422
Safety Class
IEC 61140 Class II
www.micropowerdirect.com