English
Language : 

MPM-20S Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Universal Input, 20W Miniature, PC Mount AC/DC Power Supplies
MPM-20S Series
Universal Input, 20W
Miniature, PC Mount
AC/DC Power Supplies
Key Features:
• 20W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved
• Adjustable Output
• Meets EN55022 B
• >200 kHour MTBF
• Compact PC Mount Case
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
85
264
VAC
120
370
VDC
Input Frequency
47
63
Hz
Input Current
See Model Selection Guide
Inrush Current
115 VAC
16.0
230 VAC
30.0
A Pk
EMI
Meets CISPR Pub. 22/FCC Class B
Safety Ground Leakage Current
115 VAC
230 VAC
0.1
mA
0.3
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
±2.0
%
Line Regulation
±0.5
Load Regulation
See Model Selection Guide
Ripple & Noise (20 MHz)
50
mV Pk - Pk
Hold-Up Time
115 VAC
20
230 VAC
80
mSec
Temperature Coefficient
±0.02
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Overload Protection
Typ. 110% of Output Power
General
Parameter
Conditions
Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage
Input to Ground 1,500
VAC
Output to Ground 500
EMI/RFI
Conducted
EN 55022 Level B
Electrostatic Discharge (ESD)
IEC/EN 61000-4-2 Level 3
EMC Compliance
RF Field Susceptibility
IEC/EN61000-4-3
Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Level 3 2 kV
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
150
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -25 +25 +70
°C
Case
+90
°C
Storage Temperature Range
-25
+105
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
85
%
Physical
Case Size
2.75 x 1.88 x 0.92 Inches (70.0 x 48.0 x 23.5 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
5.65 Oz (160g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 200
kHours
Safety Standards
IEN 60950, IEC 60950
Safety Approvals
IEN 60950, IEC 60950
www.micropowerdirect.com