MPM-20EPB Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-20EPB Series | |||
|
MPM-20EPB Series
Very Low Cost, 20W
Compact âPower Brickâ
AC/DC Power Supplies
Key Features:
Electrical Speciï¬cations
⢠20W Output Power
Speciï¬cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
⢠Compact 1.1 x 2.1 Inch Case Input
Parameter
Conditions
Min. Typ. Max. Units
⢠Universal 85-264 VAC Input
⢠EN 60950 Approved (UL)
Input Voltage Range
85
264
VAC
110
370
VDC
⢠Meets IEC Safety Class II Input Frequency
47
440
Hz
⢠Industry Standard Pin-Out
⢠Meets EN 55022 Class B
⢠>300 kHour MTBF
Input Current
Inrush Current
Output
See Model Selection Guide
115 VAC
20.0
230 VAC
40.0
A Pk
⢠Low, Low Cost
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
See Note 1
±2.0
%
Line Regulation
VIN = Min to Max
±0.5
%
Load Regulation
See Note 3
±1.0
%
Ripple & Noise (20 MHz)
50 120
mV P-P
Hold-Up Time
115 VAC
10
230 VAC
50
mSec
Temperature Coefï¬cient
±0.02
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Over Voltage Protection
Zener Diode Clamp
Overload Protection
Autorecovery 110
%W
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Resistance
500 VDC 100
Mï
Switching Frequency
100
kHz
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
EN 55022
Class B
Conducted Emissions
EN 55022
Class B
ESD
EN 61000-4-2 Criteria B; ±8 kV Air/±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Criteria B; ±4 kV
Surge
See Note 5 EN 61000-4-5
Criteria B; ±2 kV
CS
EN 61000-4-6
Criteria A; 10 Vrms
PFMF
EN 61000-4-8
Criteria A; 10A/m
Voltage Dips
EN 61000-4-11
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min. Typ. Max.
Ambient -40 +25 +70
Case
+95
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Units
°C
°C
°C
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Reliability Speciï¬cations
2.12 x 1.13 x 0.925 Inches (53.8 x 28.8 x 23.50 mm)
Non-Conductive Black Plastic (UL94-V0)
1.76 Oz (50g)
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
EN 60950
Safety Class
IEC 60536 Class II
www.micropowerdirect.com
|
▷ |