English
Language : 

MPM-12EPB Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-12EPB Series
MPM-12EPB Series
Very Low Cost, 12W
Compact “Power Brick”
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 12W Output Power
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• Compact 1.1 x 2.1 Inch Case Input
Parameter
Conditions
Min. Typ. Max. Units
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
Input Voltage Range
85
264
VAC
110
370
VDC
• Meets IEC Safety Class II Input Frequency
47
440
Hz
• Industry Standard Pin-Out
• Meets EN 55022 Class B
• >300 kHour MTBF
Input Current
Inrush Current
Output
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
A Pk
• Low, Low Cost
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
±2.0
%
Line Regulation
VIN = Min to Max
±0.5
%
Load Regulation
See Note 2
±1.0
%
Ripple & Noise (20 MHz)
100
mV P-P
Hold-Up Time
115 VAC
10
230 VAC
50
mSec
Temperature Coefficient
±0.02
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Over Voltage Protection
Zener Diode Clamp
Overload Protection
Autorecovery 110
%W
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 4,000
VAC
Isolation Resistance
500 VDC 100
M
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
EN 55022
Class B
Conducted Emissions
EN 55022
Class B
ESD
EN 61000-4-2 Criteria B; ±8 kV Air/±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Criteria B; ±4 kV
Surge
See Note 4 EN 61000-4-5
Criteria B; ±2 kV
CS
EN 61000-4-6
Criteria A; 10 Vrms
PFMF
EN 61000-4-8
Criteria A; 10A/m
Voltage Dips
EN 61000-4-11
Criteria B; 0% - 70%
Switching Frequency
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min. Typ. Max.
Ambient -40 +25 +70
Case
+90
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Units
°C
°C
°C
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Reliability Specifications
2.12 x 1.13 x 0.925 Inches (53.8 x 28.8 x 23.50 mm)
Non-Conductive Black Plastic (UL94-V0)
2.13 Oz (60g)
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
EN 60950
Safety Class
IEC 60536 Class II
www.micropowerdirect.com