English
Language : 

MPM-10PB Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-10PB Series
MPM-10PB Series
Single Output, 10W
Compact “Power Brick”
AC/DC Power Supplies
Key Features:
• 10W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Meets EN 55022 B
• Meets ErP Directive
• Industry Standard Pin-Out
• >300 kHour MTBF
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
85
264
VAC
120
370
VDC
Input Frequency
47
440
Hz
Input Current
See Model Selection Guide
Inrush Current
115 VAC
230 VAC
15.0
30.0
A Pk
No Load Power Consumption
0.3
W
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
±2.0
%
Line Regulation
VIN = Min to Max
±1.0
%
Load Regulation
IOUT = 10% to 100%
±1.0
%
Ripple & Noise (20 MHz), See Note 1
3.3V and 5V Models
12V, 15V, and 24V Models
1.5
0.8
1.8
1.0
% V P-P of VOUT
Hold-Up Time
115 VAC
20
230 VAC
60
mSec
Temperature Coefficient
±0.01 ±0.02 %/°C
Over Voltage Protection
Zener Diode Clamp
120
%VOUT
Over Temperature Protection
Autorecovery (at 67 °C)
90
°C
Short Circuit Protection
Continuous (Autorecovery)
Overload Protection
Foldback, Autorecovery 105
%W
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Resistance
500 VDC 100
M
Switching Frequency
125
kHz
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
EN 55022
Class B
Conducted Emissions
EN 55022
Class B
ESD
EN 61000-4-2 Criteria B; ±8 kV Air/±4 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Criteria B; ±2 kV
Surge
EN 61000-4-5
Criteria B; ±1 kV
CS
EN 61000-4-6
Criteria B; 10 Vrms
PFM
EN 61000-4-8
Criteria A; 30A/m
Voltage Dips
EN 61000-4-11
Criteria B; 10 mS
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -25 +25 +70
°C
Storage Temperature Range
-40
+105
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
85
%
Physical
Case Size
2.06 x 1.07 x 0.93 Inches (52.4 x 27.2 x 23.50 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
1.90 Oz (54g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
EN 60950
Safety Class
IEC 60536 Class II
ECO Design
ErP Directive 2009/125/EC
www.micropowerdirect.com