MPM-10EPB Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPM-10EPB Series | |||
|
MPM-10EPB Series
Very Low Cost, 10W
Compact âPower Brickâ
AC/DC Power Supplies
Key Features:
Electrical Speciï¬cations
⢠10W Output Power
Speciï¬cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
⢠Compact 1.1 x 2.1 Inch Case Input
Parameter
Conditions
Min. Typ. Max. Units
⢠Universal 85-264 VAC Input
⢠EN 60950 Approved (UL)
Input Voltage Range
85
264
VAC
110
370
VDC
⢠Meets IEC Safety Class II Input Frequency
47
440
Hz
⢠Industry Standard Pin-Out
⢠Meets EN 55022 Class A
⢠>300 kHour MTBF
⢠Low, Low Cost
Input Current
Inrush Current
Output
Parameter
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Conditions
Min. Typ. Max.
A Pk
Units
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
±2.0
%
Line Regulation
VIN = Min to Max
±0.5
%
Load Regulation
See Note 2
±1.0
%
Ripple & Noise (20 MHz)
50 100
mV P-P
Hold-Up Time
230 VAC
50
mSec
Temperature Coefï¬cient
±0.02
%/°C
Short Circuit Protection
Continuous (Autorecovery)
Overload Protection
Autorecovery 110
%W
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 4,000
VAC
Isolation Resistance
500 VDC 100
Mï
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
See Note 3
EN 55022
Class A
Conducted Emissions
See Note 3
EN 55022
Class A
ESD
EN 61000-4-2 Criteria B; ±8 kV Air/±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
See Note 4 EN 61000-4-4
Criteria B; ±2 kV
Surge
See Note 4 EN 61000-4-5
Criteria B; ±1 kV
CS
EN 61000-4-6
Criteria A; 10 Vrms
PFM
EN 61000-4-8
Criteria A; 10A/m
Voltage Dips
EN 61000-4-11
Criteria B; 0% - 70%
Switching Frequency
60
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Ambient -25 +25 +70
°C
Case
+90
°C
-40
+105
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
%
T: (781) 344-8226
Case Size
2.12 x 1.13 x 0.75 Inches (53.8 x 28.8 x 28.80 mm)
F: (781) 344-8481
Case Material
Non-Conductive Black Plastic (UL94-V0)
E: sales@micropowerdirect.com Weight
1.76 Oz (50g)
W: www.micropowerdirect.com Reliability Speciï¬cations
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 300
kHours
Safety Standards
EN 60950
Safety Class
IEC 60536 Class II
www.micropowerdirect.com
|
▷ |