English
Language : 

MPM-04V Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Compact, Board Mount 4W Ultra-Wide Input Range AC/DC Power Supplies
MPM-04V Series
Compact, Board Mount 4W
Ultra-Wide Input Range
AC/DC Power Supplies
Key Features:
• 4W Output Power
• Universal 90-305 VAC Input
• Miniature Size
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single and Dual Outputs
• Meets EN 55022 B
• >350 kHour MTBF
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
Input Frequency
90
305
VAC
120
430
VDC
47
440
Hz
Input Current
Inrush Current
See Model Selection Guide
115 VAC
15.0
230 VAC
25.0
A Pk
EMI
EMC
Meets CISPR Pub. 22/FCC Class B
Meets EN 55024
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage
See Model Selection Guide
Output Current
Output Voltage Accuracy
See Model Selection Guide
See Note 2
±2.0
%
Line Regulation, See Note 3
Load Regulation, Single Output
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Dual Output
Ripple/Noise (20 MHz)
3.3V Output, VIN = Min to Max
5V to 24V Output, VIN = Min to Max
3.3V output, IO = 0% to 100%
5V to 24V output, IO = 0% to 100%
Vout 1, IO = 10% to 100%
Vout 2, IO = 10% to 100%
Single 3.3V & 5V Outputs
All Other Models
±0.5
±0.2
±1.5
±0.5
±0.5
±5.0
150.0
100.0
%
%
%
%
%
mVP-P
Hold-Up Time
Temperature Coefficient
115 VAC
15
±0.02
mSec
%/°C
Over Voltage Protection
Short Circuit Protection, See Note 4
Zener Diode Clamp
120
Continuous (Autorecovery)
% of VO
Overload Protection
General
105 120
% of IO
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Isolation Resistance
EMI/RFI
Input to Output 3,000
500 VDC 100
Conducted
VAC
M⍀
EN 55022 Level B
EMC Compliance
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
132
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Storage Temperature Range
Ambient -40 +25 +70
°C
-40
+125
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
Physical
RH, Non-condensing
95
%
Case Size
Case Material
1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
Weight
0.91 Oz (26g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
Safety Standards
MIL HDBK 217F, 25°C, Gnd Benign 350
UL 60950, EN 60950
kHours
Safety Approvals
UL, cUL; File No. E245422
Safety Class
IEC 61140 Class II
www.micropowerdirect.com