English
Language : 

MPG-60 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MPG-60S Series
MPG-60S Series
Single & Dual Output, 60W
Green, Open Frame
AC/DC Power Supplies
Key Features:
• 60W Output Power
• 80W With Only 7 CFM
• Universal 90-264 AC Input
• EN 60950 Approved (UL)
• Meets ErP Directive
• Compact 2 x 4 Inch Size
• Meets EN 55022 B
• Optional +5V SB Output
• >400 kHour MTBF
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
Universal 90
110
264
VAC
373
VDC
Input Frequency
47
63
Hz
Input Filter
Meets EN 55022 Class B; FCC Class B
Input Current
See Model Selection Guide
Inrush Current
Cold Start, 115 VAC
Cold Start, 230 VAC
30.0
60.0
A Pk
Leakage Current
0.25
mA
No Load Power Consumption
0.5
W
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage/Current
See Model Selection Guide
Output Voltage Tolerance
See Note 1
±1.0
%
Line Regulation
See Note 2
±1.0
%
Load Regulation
See Note 3
±1.0
%
Ripple & Noise (20 MHz)
See Note 4
±1.0
%
Hold-Up Time
115 VAC
16
mSec
Temperature Coefficient
±0.05
%/°C
Over Voltage Protection
140
%
Short Circuit Protection
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Input to Output 3,000
VAC
Isolation Resistance
500 VDC
100
M⍀
Isolation Capacitance
2,200
pF
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions, See Note 5
EN 55022
Class B
Conducted Emissions , See Note 5
EN 55022
Class B
ESD
EN 61000-4-2 Criteria A; ±8 kV Air/±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Criteria A; ±2 kV Line & PE
Surge
EN 61000-4-5 Criteria A; L-N: ±1kV, L/N-PE: ±2kV
CS
EN 61000-4-6
Criteria A; 10 Vrms
PFMF
EN 61000-4-8
Criteria A; 10 Vrms
Criteria A; Volt. Dips >95%, 0.5 Cycle
Voltage Dips, See Note 6
EN 61000-4-11
Criteria A; Volt. Dips 30%, 25 Cycles
Criteria A/B; Volt. Dips 60%, 5 Cycles
Criteria B; Volt. Inter, >95%, 250 Cycles
Switching Frequency
Fixed
65
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -20 +25 +70
°C
Storage Temperature Range
-40
+85
°C
Cooling
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
95
%
Physical
Size
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
Weight
5.99 Oz (0.170 kg)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 400
kHours
Safety Standards
UL 60950, EN 60950
www.micropowerdirect.com