English
Language : 

MPG-120S Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Single Output, 120W Green, Open Frame AC/DC Power Supplies
MPG-120S Series
Single Output, 120W
Green, Open Frame
AC/DC Power Supplies
Key Features:
• 120W Output Power
• 150W With Only 7 CFM
• Universal 85-264 AC Input
• EN 60950 Approved (UL)
• Meets ErP Directive
• Compact 3 x 5 Inch Size
• PFC Meets EN 61000-3
• Optional +5V SB Output
• >400 kHour MTBF
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Power Factor Correction
Leakage Current
No Load Power Consumption
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI Characteristics
Parameter
Radiated Emissions, See Note 5
Conducted Emissions , See Note 5
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips, See Note 6
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Conditions
Min. Typ. Max.
Universal 85
264
110
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
30.0
Cold Start, 230 VAC
60.0
Meets EN 61000-3-2/3 Class A
0.25
0.5
Units
VAC
VDC
Hz
A Pk
mA
W
Conditions
Min. Typ.
See Model Selection Guide
See Note 1
±1.0
See Note 2
±1.0
See Note 3
±1.0
See Note 4
±1.0
115 VAC
20
230 VAC
40
±0.05
140
Continuous (Autorecovery)
Max.
Units
%
%
%
%
mSec
%/°C
%
Conditions
Min.
Input to Output 3,000
500 VDC
Typ.
100
2,200
Max.
Units
VAC
M⍀
pF
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Fixed
Min. Typ. Max. Units
Class B
Class B
Criteria A; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV Line & PE
Criteria A; L-N: ±1kV, L/N-PE: ±2kV
Criteria A; 10 Vrms
Criteria A; 10A/ms
Criteria A; Volt. Dips >95%, 0.5 Cycle
Criteria A; Volt. Dips 30%, 25 Cycles
Criteria A/B; Volt. Dips 60%, 5 Cycles
Criteria C; Volt. Inter, >95%, 250 Cycles
65
kHz
Conditions
Min. Typ. Max.
Ambient -20 +25 +70
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Units
°C
°C
%
5.00 x 3.00 x 1.35 Inches (127.00 x 76.20 x 34.2 mm)
9.87 Oz (0.280 kg)
Conditions
Min. Typ.
MIL HDBK 217F, 25°C, Gnd Benign 400
UL 60950, EN 60950
Max.
Units
kHours
www.micropowerdirect.com