English
Language : 

ML200SEI Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – 2W, High Isolation Ultra-Miniature SMT DC/DC Converters
ML200SEI Series
2W, High Isolation
Ultra-Miniature SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• Ultra-Miniature SMT Case
• 3,000 VDC Isolation
Input
Parameter
Input Voltage Range
Conditions
Min. Typ. Max.
5 VDC Input 4.5 5.0 5.5
12 VDC Input 10.8 12.0 13.2
15 VDC Input 13.5 15.0 16.5
Units
VDC
• Single Output
24 VDC Input 21.6 24.0 26.4
• -40°C to +105°C Operation Input Filter
Capacitor
• >3.5 MHour MTBF
Output
• 13 Standard Models
• LOW COST!
Parameter
Output Voltage Accuracy
Capacitive Load
Conditions
Min. Typ. Max.
±3.0
220
Units
%
µF
Line Regulation
For Vin Change of 1%
±1.2
%
Load Regulation, See Note 1
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 2
100 200 mV P - P
Temperature Coefficient
±0.03 %/ºC
Output Short Circuit
Momentary (1S Max)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 3,000
VDC
Isolation Resistance
500 VDC 1,000
M⍀
Isolation Capacitance
100 kHz, 0.1V
20
pF
Switching Frequency
100
kHz
EMI Characteristics
Parameter
Standard
Criteria
Level
Radiated Emissions
EN 55022
B
Conducted Emissions
EN 55022
B
ESD
EN 61000-4-2
B
±8kV
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +105
ºC
Storage Temperature Range
-55
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
0.05 Oz (1.52g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25ºC, Gnd Benign 3.5
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
Input Voltage Surge (1 Sec)
Conditions
Min. Typ. Max.
5 VDC Input -0.7
9.0
12 VDC Input -0.7
18.0
15 VDC Input -0.7
21.0
Units
VDC
24 VDC Input -0.7
30.0
Peak Reflow Temperature
See Note 5
245
ºC
Lead Temperature
1.5 mm From Case For 10 Sec
300
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com