Key Features:
⢠2W Output Power
⢠4 kVAC rms Isolation
⢠Reinforced Insulation
⢠Low Leakage Current
⢠Compact SMT Case
⢠Single & Dual Outputs
⢠2.0 MH MTBF
⢠Industry Standard Pin-Out
⢠EN 60950 Approved
⢠EN 60601 Approved
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Speciï¬cations
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
5 VDC Input 4.5 5.0 5.5
Input Voltage Range
12 VDC Input 10.8 12.0 13.2
VDC
24 VDC Input 21.6 24.0 26.4
Input Filter
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Leakage Current
2.0
µA
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±2.0 ±4.0
%
Output Voltage Balance
Dual Outputs, Balanced Loads
±0.1 ±1.0
%
Line Regulation
Vin = Min to Max
±1.2 ±1.5
%
Load Regulation, See Note 1
See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2
100 150 mV P - P
Ripple & Noise (20 MHz)
Over Line, Load & Temp.
200 mV P - P
Ripple & Noise (20 MHz)
15 mV rms
Temperature Coefï¬cient
±0.01 ±0.02 %/°C
Output Short Circuit
Momentary (0.5 Sec.)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, Rated
60 Seconds 4,000
VAC rms
Isolation Test Voltage
Flash Tested For 1 Sec 6,000
VPk
Reinforced Insulation Working Voltage
300
VAC
Isolation Resistance
500 VDC 10
Gâ
Isolation Capacitance
100 kHz, 1V
15 20
pF
Switching Frequency
50 80 100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -25
+80
°C
Operating Temperature Range
Case
+90
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
0.94 x 0.54 x 0.35 Inches (24.0 x 13.7 x 9.00 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.14 Oz (3.75g)
Reliability Speciï¬cations
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 2.0
MHours
Safety Approvals
UL 60601, UL 60950, EN 60601, EN 60950
Moisture Sensitivity Level
IPC/JEDEC J-STD-020C Level 2
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
5 VDC Input -0.7
9.0
Input Voltage Surge (1 Sec)
12 VDC Input -0.7
18.0
VDC
24 VDC Input -0.7
30.0
Lead Temperature
1.5 mm From Case For 10 Sec
260
°C
Internal Power Dissipation
All Models
650
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.