English
Language : 

ML100RW Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Ultra-Compact, 1W Wide 2:1 Input, SMT DC/DC Con vert ers
ML100RW Series
Ultra-Compact, 1W
Wide 2:1 Input, SMT
DC/DC Converters
Key Features:
• 1W Output Power
• Ultra-Compact SMT Case
• Wide 2:1 Input
• 1,500 VDC Isolation
• Single & Dual Outputs
• -40ºC to +85ºC Operation
• 20 Standard Models
• Tight Line/Load Regulation
• Available on Tape/Reel
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Start Up Voltage
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Response Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off
Parameter
Supply On
Supply Off
Standby Input Current
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Moisture Sensitivity Level (MSL)
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
Conditions
Min. Typ. Max.
5 VDC Input 4.5 5.0 9.0
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
5 VDC Input
4.5
12 VDC Input
9.0
24 VDC Input
18.0
48 VDC Input
36.0
Capacitor
Units
VDC
VDC
Single
Dual
Conditions
Min. Typ.
At 50% Load
For VIN = Min to Max
For IOUT = Min to Max
For IOUT = 10% to 100%
See Note 2
30
25% Load Step Change
250
±3
Continuous (Autorecovery)
Max.
±1.0
±0.2
±1.0
±0.5
±0.8
±0.02
Units
%
%
%
mV P - P
µS
%
%/ºC
Conditions
Min. Typ.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
220
Max.
50
Units
VDC
M
pF
kHz
Conditions
See Note 4
Min. Typ. Max. Units
Open or High Impedance
2.0
4.0
mA
2.5
mA
Conditions
Min. Typ.
Ambient -40
Case
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+95
+125
95
Units
ºC
ºC
ºC
%
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.15 Oz (4.5g)
Conditions
Min. Typ. Max. Units
MIL HDBK 217F, 25ºC, Gnd Benign 2.80
MHours
IPC/JEDEC J-STD-020D Level 2
Conditions
Min. Typ. Max. Units
5 VDC Input -0.7
15.0
12 VDC Input -0.7
24 VDC Input -0.7
25.0
50.0
VDC
48 VDC Input -0.7
100.0
See Note 5
245
ºC
1.5 mm From Case For 10 Sec.
260
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com