ML100RW Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Ultra-Compact, 1W Wide 2:1 Input, SMT DC/DC Con vert ers | |||
|
ML100RW Series
Ultra-Compact, 1W
Wide 2:1 Input, SMT
DC/DC Converters
Key Features:
⢠1W Output Power
⢠Ultra-Compact SMT Case
⢠Wide 2:1 Input
⢠1,500 VDC Isolation
⢠Single & Dual Outputs
⢠-40ºC to +85ºC Operation
⢠20 Standard Models
⢠Tight Line/Load Regulation
⢠Available on Tape/Reel
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Speciï¬cations
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
Parameter
Input Voltage Range
Start Up Voltage
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Response Time, See Note 3
Transient Response Deviation
Temperature Coefï¬cient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off
Parameter
Supply On
Supply Off
Standby Input Current
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Speciï¬cations
Parameter
MTBF
Moisture Sensitivity Level (MSL)
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Peak Reï¬ow Temperature
Lead Temperature
Conditions
Min. Typ. Max.
5 VDC Input 4.5 5.0 9.0
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
5 VDC Input
4.5
12 VDC Input
9.0
24 VDC Input
18.0
48 VDC Input
36.0
Capacitor
Units
VDC
VDC
Single
Dual
Conditions
Min. Typ.
At 50% Load
For VIN = Min to Max
For IOUT = Min to Max
For IOUT = 10% to 100%
See Note 2
30
25% Load Step Change
250
±3
Continuous (Autorecovery)
Max.
±1.0
±0.2
±1.0
±0.5
±0.8
±0.02
Units
%
%
%
mV P - P
µS
%
%/ºC
Conditions
Min. Typ.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
220
Max.
50
Units
VDC
Mï
pF
kHz
Conditions
See Note 4
Min. Typ. Max. Units
Open or High Impedance
2.0
4.0
mA
2.5
mA
Conditions
Min. Typ.
Ambient -40
Case
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+95
+125
95
Units
ºC
ºC
ºC
%
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.15 Oz (4.5g)
Conditions
Min. Typ. Max. Units
MIL HDBK 217F, 25ºC, Gnd Benign 2.80
MHours
IPC/JEDEC J-STD-020D Level 2
Conditions
Min. Typ. Max. Units
5 VDC Input -0.7
15.0
12 VDC Input -0.7
24 VDC Input -0.7
25.0
50.0
VDC
48 VDC Input -0.7
100.0
See Note 5
245
ºC
1.5 mm From Case For 10 Sec.
260
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |