English
Language : 

MI600ERW Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – MI600ERW SERIES
MI600ERW Series
2:1 Input, 6W,
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 6W Output Power
Input
Parameter
Conditions
Min. Typ. Max.
12 VDC Input 9.0 12.0 18.0
Units
• 2:1 Input Voltage Range Input Voltage Range
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
VDC
• Miniature 1” x 1” Case
• 1,500 VDC Isolation
Input Start Voltage
12 VDC Input
24 VDC Input
48 VDC Input
9.0
18.0
VDC
36.0
• 24 Standard Models
• Single & Dual Outputs
Input Filter
Output
Parameter
Conditions
Pi (␲) Filter
Min. Typ. Max.
Units
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Chassis Mount Option
• DIN Rail Option
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Ripple (20 MHz)
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 1
See Note 2
±1.0 ±2.0
%
±0.5 ±1.5
%
±0.2 ±0.5
%
±0.5 ±1.0
%
±5.0
%
15
25 mV P - P
Noise (20 MHz)
See Note 2
50
75 mV P - P
Transient Recovery Time, See Note 3
Transient Response Deviation
25% Load Step Change
300 500
±3.0 ±5.0
µSec
%
Temperature Coefficient
±0.03 %/°C
Output Over Voltage Protection
Output Short Circuit
General
110 120 140
Continuous (Autorecovery)
%VOUT
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Isolation Resistance
60 Seconds 1,500
500 VDC 1,000
VDC
M
Isolation Capacitance
1,000
pF
Switching Frequency
300
kHz
EMI Characteristics
Parameter
Standard
Level
Radiated Emissions
See Note 4
EN 55022
Class A
Conducted Emissions
See Note 4
EN 55022
Class A
ESD
EN 61000-4-2
Criteria B; ±4 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
See Note 5
See Note 5
EN 61000-4-4
EN 61000-4-4
Criteria B; ±2 kV
Criteria B; ±4 kV
Surge
See Note 6 EN 61000-4-5
Criteria B; ±2 kV
CS
EN 61000-4-6
Criteria A; 3 Vrms
Voltage Dips
Environmental
EN 61000-4-29
Criteria B; 0% - 70%
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+105
°C
MicroPower Direct
Storage Temperature Range
Cooling
-55
Free Air Convection
+125
°C
292 Page Street
Humidity
RH, Non-condensing
95
%
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Aluminum (UL94-V0)
0.46 Oz (15g)
Conditions
Min. Typ. Max. Units
MIL HDBK 217F, 25°C, Gnd Benign 1.0
MHours
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com