MI600ERW Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – MI600ERW SERIES | |||
|
MI600ERW Series
2:1 Input, 6W,
Ultra-Miniature
DC/DC Converters
Electrical Speciï¬cations
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Key Features:
⢠6W Output Power
Input
Parameter
Conditions
Min. Typ. Max.
12 VDC Input 9.0 12.0 18.0
Units
⢠2:1 Input Voltage Range Input Voltage Range
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
VDC
⢠Miniature 1â x 1â Case
⢠1,500 VDC Isolation
Input Start Voltage
12 VDC Input
24 VDC Input
48 VDC Input
9.0
18.0
VDC
36.0
⢠24 Standard Models
⢠Single & Dual Outputs
Input Filter
Output
Parameter
Conditions
Pi (â²) Filter
Min. Typ. Max.
Units
⢠-40°C to +85°C Operation
⢠Industry Standard Pin-Out
⢠Chassis Mount Option
⢠DIN Rail Option
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Ripple (20 MHz)
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 1
See Note 2
±1.0 ±2.0
%
±0.5 ±1.5
%
±0.2 ±0.5
%
±0.5 ±1.0
%
±5.0
%
15
25 mV P - P
Noise (20 MHz)
See Note 2
50
75 mV P - P
Transient Recovery Time, See Note 3
Transient Response Deviation
25% Load Step Change
300 500
±3.0 ±5.0
µSec
%
Temperature Coefï¬cient
±0.03 %/°C
Output Over Voltage Protection
Output Short Circuit
General
110 120 140
Continuous (Autorecovery)
%VOUT
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Isolation Resistance
60 Seconds 1,500
500 VDC 1,000
VDC
Mï
Isolation Capacitance
1,000
pF
Switching Frequency
300
kHz
EMI Characteristics
Parameter
Standard
Level
Radiated Emissions
See Note 4
EN 55022
Class A
Conducted Emissions
See Note 4
EN 55022
Class A
ESD
EN 61000-4-2
Criteria B; ±4 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
See Note 5
See Note 5
EN 61000-4-4
EN 61000-4-4
Criteria B; ±2 kV
Criteria B; ±4 kV
Surge
See Note 6 EN 61000-4-5
Criteria B; ±2 kV
CS
EN 61000-4-6
Criteria A; 3 Vrms
Voltage Dips
Environmental
EN 61000-4-29
Criteria B; 0% - 70%
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+105
°C
MicroPower Direct
Storage Temperature Range
Cooling
-55
Free Air Convection
+125
°C
292 Page Street
Humidity
RH, Non-condensing
95
%
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Reliability Speciï¬cations
Parameter
MTBF
Absolute Maximum Ratings
Parameter
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Aluminum (UL94-V0)
0.46 Oz (15g)
Conditions
Min. Typ. Max. Units
MIL HDBK 217F, 25°C, Gnd Benign 1.0
MHours
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |