English
Language : 

MI600ERU Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MI600ERU SERIES
MI600ERU Series
4:1 Input, 6W
Ultra-Miniature
DC/DC Converters
Key Features:
• 6W Output Power
• 4:1 Input Range
• Miniature 1” x 1” Case
• Single & Dual Outputs
• 1,500 VDC Isolation
• >1 MHour MTBF
• 16 Standard Models
• LOW COST!!
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
24 VDC Input 9.0 24.0 36.0
48 VDC Input 18.0 48.0 75.0
VDC
Input Filter
Pi (␲) Filter
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0 ±2.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±0.5 ±1.5
%
Line Regulation
Vin = Min to Max
±0.2 ±0.5
%
Load Regulation, See Note 1
Iout = 5% to 100%
±0.5 ±1.0
%
Ripple (20 MHz)
See Note 2
15 25 mV P - P
Noise (20 MHz)
See Note 2
50 75 mV P - P
Transient Recovery Time , See Note 3
Transient Response Deviation
25% Load Step Change
300 500
±3.0 ±5.0
µSec
%
Temperature Coefficient
±0.03
%/ºC
Output Over Voltage Protection
110
140
%VOUT
Output Over Load Protection
120
180
%IOUT
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz, 1V
1,000
pF
Switching Frequency
300
kHz
EMI Characteristics
Parameter
Standard
Min. Typ. Max. Units
Radiated Emissions
See Note 4
EN 55022
Class A
Conducted Emissions
See Note 4
EN 55022
Class A
ESD
EN 61000-4-2
Criteria B; ±4 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
See Note 5
EN 61000-4-4
Criteria B; ±2 kV
Surge
See Note 6
EN 61000-4-5
Criteria B; ±2 kV
CS
EN 61000-4-6
Criteria A; 3 Vrms
Voltage Dips
EN 61000-4-29
Criteria B; 0% - 70%
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+85
ºC
Operating Temperature Range
Case
+105
ºC
Storage Temperature Range
-55
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Case Material
Aluminum (UL94-V0)
Weight
0.48 Oz (14g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign 1.0
MHours
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
48 VDC Input -0.7
50.0
100.0
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
300
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com