MI2500RU Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – Compact, 25W, 4:1 Input Range DC/DC Con vert ers | |||
|
MI2500RU Series
Compact, 1 x 1 Inch
25W, 4:1 Input Range
DC/DC Converters
Electrical Speciï¬cations
Key Features:
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
⢠25W Output Power
⢠4:1 Input Voltage Range
⢠Compact 1 x 1 Inch Case
Input Start Voltage
Input Filter
Start-Up Time
24 VDC Input
48 VDC Input
LC Filter
See Note 1
9.0
18.0
VDC
30
mS
⢠1,500 VDC Isolation
⢠12 Standard Models
⢠Efï¬ciency to 90%
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Conditions
Min. Typ.
Dual Output, Balanced Loads
Max.
±1.0
±2.0
Units
%
%
⢠Wide Temp Operation
Line Regulation
⢠Industry Standard Pin-Out Load Regulation, Min Load to Full Load
VIN = Min to Max
Single Output
Dual Output
±0.2
%
±0.2
±1.0
%
Cross Regulation, Dual Outputs
Asymmetrical Load 25%/100%
±5.0
%
Ripple & Noise, See Note 2
3.3 & 5.0 Vout Models
12, 15 & Dual Output Models
100
150
mV P - P
Transient Recovery Time, See Note 3
Transient Response Deviation
25% Load Step Change
250
±3.0
±5.0
µSec
%
Temperature Coefï¬cient
±0.02 %/°C
Output Power Protection
150
%
Output Short Circuit, See Note 4
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Isolation Resistance
60 Seconds 1,500
500 VDC 1,000
VDC
Mâ
Isolation Capacitance
100 kHz, 1V
2,000
pF
Switching Frequency
Environmental
285
kHz
Parameter
Conditions
Min. Max Max. Units
No Hsink Heatsink
MI2548S-03RU
+57
+65
Operating Temperature Range,
Ambient Without Heatsink
MI2524S-15RU, MI2548S-05RU
MI2548S-12RU, MI2548S-15RU
+56
+64
MI2524S-03RU -40 +53
+61
°C
MI2524S-05RU, MI2524S-12RU
MI2524D-12RU, MI2524D-15RU
+50
+59
MI2548D-12RU, MI2448D-15RU
Operating Temperature Range
Case
+105
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
Physical
Case Size
Case Material
Weight
Reliability Speciï¬cations
RH, Non-condensing
95
%
See Mechanical Diagrams (Page 4)
Metal with Non-Conductive Base
0.58 Oz (16.5g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ.
MIL HDBK 217F, 25°C, Gnd Benign 315
Conditions
Min. Typ.
Max. Units
kHours
Max. Units
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
48 VDC Input -0.7
50.0
100.0
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
260.0
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |