English
Language : 

MHI300ARWI8 Datasheet, PDF (1/3 Pages) MicroPower Direct, LLC – Wide Input, 3W DIP Ultra-High Isolation DC/DC Converters
MHI300ARWI8Series
Wide Input, 3W DIP
Ultra-High Isolation
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 3W Output Power
• 8.0 kV Isolation
• 15 kV/µS CMTI
Parameter
Input Voltage Range
Conditions
Min. Typ. Max.
5 VDC Input 4.5 5.0 5.5
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
Units
VDC
• Wide 2:1 Input Range
• Reinforced Insulation
Start-Up Threshold Voltage
5 VDC Input 3.7 4.0 4.5
12 VDC Input 8.0 8.5 9.0
24 VDC Input 15.0 17.0 18.0
VDC
• EN 60950 Approved (Pend.)
• -40°C to +85°C Operation
Under Voltage Shutdown
• Industry Standard Pin-Out
48 VDC Input 30.0 33.0 36.0
5 VDC Input
4.0
12 VDC Input
8.5
24 VDC Input
17.0
48 VDC Input
34.0
VDC
Short Circuit Input Power
Input Filter
␲ (Pi) Filter
2,000
mW
Conducted EMI
Output
Meets EN 55022 Class A & FCC Level A
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±0.5 ±2.0
%
Line Regulation
Load Regulation
VIN = Min to Max
See Note 2
±0.3 ±0.5
%
±0.5 ±1.0
%
Ripple & Noise (20 MHz)< See Note 3
5 VDC Output Models
All Other Models
75
100
100
150
mV P - P
Transient Recovery Time, See Note 4
Transient Response Deviation
25% Load Step Change
150 500
±3.0 ±6.0
µSec
%
Output Power Protection
Foldback 120 150
%
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Short Circuit
General
Continuous (Autorecovery)
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, 60 Sec
Isolation Resistance
Rated For 60 Sec 4,000
Tested For 1 Sec 8,000
500 VDC 10
VAC rms
VDC
G
Isolation Capacitance
100 kHz, 1V
7
13
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
Environmental
150
kHz
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
Case
+100
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
MicroPower Direct
Humidity
Physical
RH, Non-condensing
95
%
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Size
Case Material
Weight
Reliability Specifications
Parameter
Conditions
See Mechanical Diagram (Page 3)
Non-Conductive Black Plastic (UL94-V0)
0.54 Oz (16.2g)
Min. Typ. Max. Units
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MTBF
Safety Standards
Absolute Maximum Ratings
Parameter
MIL HDBK 217F, 25°C, Gnd Benign 1.0
UL 60950, EN 60950 (Pending)
Conditions
Min. Typ. Max.
5 VDC Input
11.0
MHours
Units
Input Voltage Surge (0.1 Sec)
12 VDC Input
25.0
VDC
24 VDC Input
50.0
48 VDC Input
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com