English
Language : 

MHI300ARUI8 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Wide Input, 3W DIP Ultra-High Isolation DC/DC Converters
MHI300ARUI8Series
Wide Input, 3W DIP
Ultra-High Isolation
DC/DC Converters
Electrical Specifications
Key Features:
• 3W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
• 8.0 kV Isolation
• 15 kV/µS CMTI
• Wide 4:1 Input Range
Input Voltage Range
Start-Up Threshold Voltage
24 VDC Input 9.0 24.0 40.0
48 VDC Input 18.0 48.0 80.0
24 VDC Input 8.0 8.5 9.0
48 VDC Input 13.0 15.0 17.0
VDC
VDC
• Reinforced Insulation
• EN 60950 Approved (Pend.)
• -40°C to +85°C Operation
Under Voltage Shutdown
Short Circuit Input Power
Input Filter
24 VDC Input
48 VDC Input
␲ (Pi) Filter
8.5
16.0
2,000
VDC
mW
• Industry Standard Pin-Out Conducted EMI
Output
Meets EN 55022 Class A & FCC Level A
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±0.5 ±2.0
%
Line Regulation
VIN = Min to Max
±0.3 ±0.5
%
Load Regulation
See Note 2
±0.5 ±1.0
%
Ripple & Noise (20 MHz)< See Note 3
5 VDC Output Models
All Other Models
75
100
100
150
mV P - P
Transient Recovery Time, See Note 4
Transient Response Deviation
25% Load Step Change
150 500
±3.0 ±6.0
µSec
%
Output Power Protection
Foldback 120 150
%
Temperature Coefficient
±0.02 ±0.05 %/°C
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, 60 Sec
Rated For 60 Sec 4,000
Tested For 1 Sec 8,000
VAC rms
VDC
Isolation Resistance
500 VDC 10
G
Isolation Capacitance
100 kHz, 1V
7
13
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
150
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
Case
+25 +85
+100
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
RH, Non-condensing
95
%
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.54 Oz (16.2g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
MTBF
Safety Standards
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
UL 60950, EN 60950 (Pending)
Max.
Units
MHours
Conditions
Min. Typ. Max. Units
Input Voltage Surge (0.1 Sec)
24 VDC Input
48 VDC Input
50.0
100.0
VDC
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com