English
Language : 

MHI300ARI6 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Compact, 3W DIP Ultra-High Isolation DC/DC Converters
MHI300ARI6 Series
Compact, 3W DIP
Ultra-High Isolation
DC/DC Converters
Key Features:
• 3W Output Power
• 6.0 kV Isolation
• 15 kV/µS CMTI
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
5 VDC Input 4.5 5.0 5.5
Input Voltage Range
12 VDC Input 10.8 12.0 13.2
VDC
24 VDC Input 21.6 24.0 26.4
• Reinforced Insulation
Short Circuit Input Power
2,500
mW
• EN 60950 Approved (Pend.) Input Filter
• Compact DIP Case
Conducted EMI
Output
• -25°C to +75°C Operation Parameter
␲ (Pi) Filter
Meets EN 55022 Class A & FCC Level A
Conditions
Min. Typ. Max.
Units
• Industry Standard Pin-Out Output Voltage Accuracy
±4.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±2.0 ±4.0
%
Line Regulation
VIN = Min to Max
±0.3 ±0.5
%
Load Regulation
See Note 2
±0.5 ±1.0
%
Ripple & Noise (20 MHz)
See Note 3
50 mV P - P
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, 60 Sec
Rated For 60 Sec 3,000
Tested For 1 Sec 6,000
VAC rms
VDC
Isolation Resistance
500 VDC 10
G
Isolation Capacitance
100 kHz, 1V
20
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
25 60
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +75
°C
Case
+95
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 2)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Non-Conductive Black Plastic (UL94-V0)
0.41 Oz (12.4g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Safety Standards
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
UL 60950, EN 60950 (Pending)
Conditions
Min. Typ. Max.
5 VDC Input
7.5
12 VDC Input
15.0
Units
VDC
24 VDC Input
30.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com