English
Language : 

MHI200GRI8 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Compact, 2W MiniDIP Ultra-High Isolation DC/DC Converters
MHI200GRI8 Series
Compact, 2W MiniDIP
Ultra-High Isolation
DC/DC Converters
Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 2W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• 8.0 kV Isolation
• 15 kV/µS CMTI
Input Voltage Range
• EN 60950 Approved (Pend.)
Input Filter
• Reinforced Insulation
Output
• Compact MiniDIP Case Parameter
5 VDC Input 4.5 5.0 5.5
12 VDC Input 10.8 12.0 13.2
24 VDC Input 21.6 24.0 26.4
Capacitor Filter
Conditions
Min. Typ. Max.
VDC
Units
• -25°C to +80°C Operation Output Voltage Accuracy
±2.0 ±4.0
%
• Industry Standard Pin-Out Output Voltage Balance
Dual Output, Balanced Loads
±0.1 ±1.0
%
Line Regulation
VIN = Min to Max
±1.2 ±1.5
%
Load Regulation, See Note 2
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 3
150 mV P - P
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Short Circuit
Momentary (0.5S Max)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Rated For 60 Sec 4,000
Tested For 1 Sec 8,000
VAC rms
VDC
Isolation Resistance
500 VDC 10
G
Isolation Capacitance
100 kHz, 1V
15 20
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
50 80 100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -25 +25 +80
°C
Case
+105
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
0.17 Oz (5.1g)
Conditions
Min. Typ.
MIL HDBK 217F, 25°C, Gnd Benign 2.0
UL 60950, EN 60950 (Pending)
Max.
Units
MHours
Conditions
Min. Typ. Max.
5 VDC Input
9.0
12 VDC Input
18.0
Units
VDC
24 VDC Input
30.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com