English
Language : 

MHI200DI5.7 Datasheet, PDF (1/3 Pages) MicroPower Direct, LLC – High Isolation, 2W SIP Single & Dual Output DC/DC Converters
MHI200DI5.7Series
High Isolation, 2W SIP
Single & Dual Output
DC/DC Converters
Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 2W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• 5.7 kV Isolation
• 15 kV/µS CMTI
• 40 Standard Models
• Miniature SIP Case
Input Voltage Range
Input Filter
5 VDC Input 4.5 5.0 5.5
12 VDC Input 10.8 12.0 13.2
15 VDC Input 13.5 15.0 16.5
24 VDC Input 21.6 24.0 26.4
Capacitor Filter
VDC
• -40°C to +80°C Operation Output
• Industry Standard Pin-Out Parameter
Conditions
Min. Typ. Max. Units
• Low Cost
Output Voltage Accuracy
Output Voltage Balance
Dual Output, Balanced Loads
±5.0
%
±0.1 ±1.0
%
Line Regulation
For VIN Change of 1%
±1.2
%
Load Regulation, See Note 2
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 3
100 mV P - P
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Short Circuit
Momentary (0.5S Max)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Rated For 60 Sec 5,200
Tested For 1 Sec 5,700
VDC
Isolation Resistance
500 VDC 10
G
Isolation Capacitance
100 kHz, 1V
7
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +80
°C
Case
+95
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 3)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
0.08 Oz (2.4g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 2.0
Units
MHours
Conditions
Min. Typ. Max.
5 VDC Input
9.0
12 VDC Input
18.0
15 VDC Input
20.0
Units
VDC
24 VDC Input
30.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com