Electrical Specifications
Key Features:
• 10W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
• 8.0 kV Isolation
• 15 kV/µS CMTI
Input Voltage Range
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
48 VDC Input 36.0 48.0 75.0
VDC
• Reinforced Insulation
• EN 60950 Approved (Pend.) Start-Up Threshold Voltage
12 VDC Input 7.0 8.0 9.0
24 VDC Input 13.0 15.0 18.0
48 VDC Input 30.0 33.0 36.0
VDC
• Wide 2:1 Input Range
• Compact 1” x 2” Case
Under Voltage Shutdown
12 VDC Input
24 VDC Input
48 VDC Input
8.5
16.0
VDC
34.0
• -40°C to +75°C Operation Short Circuit Input Power
3,000
mW
Input Filter
␲ (Pi) Filter
Conducted EMI
Meets EN 55022 Class A & FCC Level A
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±0.5 ±2.0
%
Line Regulation
VIN = Min to Max
±0.3 ±0.5
%
Load Regulation
See Note 2
±0.5 ±1.0
%
Ripple & Noise (20 MHz)< See Note 3
5 VDC Output Models
All Other Models
100
150
mV P - P
Transient Recovery Time, See Note 4
Transient Response Deviation
25% Load Step Change
300 600
±3.0 ±6.0
µSec
%
Output Power Protection
120 150
%
Temperature Coefficient
±0.02 ±0.05 %/°C
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, 60 Sec
Rated For 60 Sec 4,000
Tested For 1 Sec 8,000
VAC rms
VDC
Isolation Resistance
500 VDC 10
G
Isolation Capacitance
100 kHz, 1V
60 80
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
120 150 180
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +75
Case
+95
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
RH, Non-condensing
95
%
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.86 Oz (24.5g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
MTBF
Safety Standards
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
UL 60950, EN 60950 (Pending)
Conditions
Min. Typ. Max.
Units
MHours
Units
12 VDC Input
25.0
Input Voltage Surge (0.1 Sec)
24 VDC Input
50.0
VDC
48 VDC Input
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com