MB4000RW Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – MB4000RW SERIES | |||
|
MB4000RWSeries
Compact, 1 x 2 Inch
40W, 2:1 Input Range
DC/DC Converters
Electrical Speciï¬cations
Key Features:
⢠40W Output Power
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input
9.0
⢠2:1 Input Voltage Range
⢠1,500 VDC Isolation
Input Start Voltage
24 VDC Input
48 VDC Input
12 VDC Input
18.0
36.0
8.3
VDC
⢠Single & Dual Outputs
⢠Efï¬ciency to 91%
Input Shutdown Voltage
Input Filter
24 VDC Input
16.5
48 VDC Input
33.0
LC Filter
VDC
⢠Compact 1 x 2 Inch Case Start-Up Time
Output
⢠Wide Temp Operation
Parameter
See Note 1
30
Conditions
Min. Typ. Max.
mS
Units
⢠Industry Standard Pin-Out Output Voltage Accuracy
Output Voltage Balance
⢠Low Cost
Line Regulation
Dual Output , Balanced Loads
VIN = Min to Max
±1.0
%
±2.0
%
±0.5
%
Load Regulation, Min Load to Full Load
Single Output Models
Dual Output Models
±0.5
±1.0
%
Cross Regulation
See Note 2
±5.0
%
3.3 & 5.0 Vout Models
100
mV P - P
Ripple & Noise, See Note 3
12, 15 & 24 Vout Models
150
mV P - P
Dual Output Models
150
mV P - P
Transient Recovery Time, See Note 4
Transient Response Deviation
25% Load Step Change
250
±3.0 ±5.0
µSec
%
Temperature Coefï¬cient
±0.02 %/°C
Over Temperature Protection
Shutdown Temperature
110
°C
Output Power Protection
150
%
Output Short Circuit, See Note 5
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
Mâ
Isolation Capacitance
100 kHz, 1V
1,500
pF
Switching Frequency
See Note 6
320
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range,
Ambient Without Heatsink
MB40xxS-03RW
+66
MB40xxS-05RW, -12RW, -15RW, -24RW -40 +25 +46
°C
MB40xxD-xxRW
+40
Operating Temperature Range,
Ambient With Heatsink
MB40xxS-03RW
+73
MB40xxS-05RW, -12RW, -15RW, -24RW -40 +25 +57
°C
MB40xxD-xxRW
+52
Operating Temperature Range
Case
+105
°C
Storage Temperature Range
-50
+125
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Cooling
Humidity
Physical
Case Size, See Note On Page 4
Case Material
Weight
Free Air Convection
RH, Non-condensing
95
%
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Metal with Non-Conductive Base
1.06 Oz (30g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Speciï¬cations
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 328
Conditions
Min. Typ. Max.
Units
kHours
Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case For 10 Sec
260.0
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |