English
Language : 

MB1000MHI Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MB1000MHI
MB1000MHI
Medical Approved, 10W
Compact 1 x 2 Inch
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 10W Output Power
• 4.2 kVAC rms Isolation
• Reinforced Insulation
• 10 µA Leakage Current Max
• Wide 2:1 Input Range
• Compact 1 x 2 In Case
• Single & Dual Outputs
• Meets EN55022
• 1.0 MH MTBF
• EN 60950 Approved
• EN 60601 Approved
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Input
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input 7.0 8.0 9.0
Input Start Voltage
24 VDC Input 13.0 15.0 18.0
VDC
48 VDC Input 30.0 33.0 36.0
12 VDC Input
8.5
Under Voltage Shutdown
24 VDC Input
16.0
VDC
48 VDC Input
34.0
Input Filter
␲ (Pi) Filter (Complies with EN55022 Class A)
Leakage Current
240 VAC, 60 Hz
10
µA
Short Circuit Input Power
3,000
mW
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0
%
Output Voltage Balance
Dual Output , Balanced Loads
±0.5 ±2.0
%
Line Regulation
VIN = Min to Max
±0.3 ±0.5
%
Load Regulation
IOUT = 15% to 100%
IOUT = 5% to 100%
±0.5 ±1.0
±0.6 ±1.2
%
Ripple & Noise (20 MHz), See Note 1
5V/5.1V Output
All Other Outputs
75
100
100
150
mV P - P
Output Power Protection
120 150
%
Transient Recovery Time, See Note 2
Transient Response Deviation
25% Load Step Change
300 600
±3.0 ±5.0
µSec
%
Temperature Coefficient
±0.02 ±0.05 %/ºC
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, Rated
60 Seconds 4,200
VAC rms
Isolation Test Voltage
Flash Tested For 1 Sec 6,000
VPk
Reinforced Insulation Working Voltage
300
VAC
Isolation Resistance
500 VDC 10
G⍀
Isolation Capacitance
100 kHz, 1V
60 80
pF
Switching Frequency
120 150 180
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+75
ºC
Operating Temperature Range
Case
+95
ºC
Storage Temperature Range
-50
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
2.00 x 1.00 x 0.47 Inches (50.8 x 25.4 x 12.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.86 Oz (24.5g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign 1.0
MHours
Safety Approvals
UL 60601, UL 60950, EN 60601, EN 60950
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case For 10 Sec
260
ºC
Internal Power Dissipation
All Models
4,000
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com