English
Language : 

MA600RWI Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MA600RWI SERIES
MA600RWI Series
Wide 2:1 Input, 6W,
High 3 kVDC Isolation
DC/DC Converters
Key Features:
• 6W Output Power
• 2:1 Input Voltage Range
• 3,000 VDC Isolation
• 24 Standard Models
• Single & Dual Outputs
• Compact DIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
1.5 kV Isolation
Models
Available
4:1 Input Range
Models
Available
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input 7.0 8.0 9.0
Input Start Voltage
24 VDC Input 14.0 16.0 18.0
VDC
48 VDC Input 32.0 34.0 36.0
12 VDC Input
8.5
Under Voltage Shutdown
24 VDC Input
16.0
VDC
Input Filter
Output
Parameter
48 VDC Input
35.0
␲ (Pi) Filter
Conditions
Min. Typ. Max.
Units
Output Voltage Accuracy
±1.0 ±2.0
%
Output Voltage Balance
Dual Output, Balanced Loads
±1.0 ±2.0
%
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
VIN = Min to Max
IOUT = 0% to 100%
See Note 1
Over Line, Load & Temp.
±0.1
±0.6
±0.5
±1.2
70
100
%
%
mV P - P
Transient Recovery Time, See Note 2
Transient Response Deviation
25% Load Step Change
300 600
±3.0
µSec
%
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Overload Protection
Foldback 110 145
%
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
Isolation Resistance
60 Seconds 3,000
500 VDC 1,000
VDC
M
Isolation Capacitance
100 kHz/1.0V
1,000
pF
Switching Frequency
330
kHz
EMI Characteristics
Parameter
Standard
Level
Radiated Emissions
EN 55022
Class A
Conducted Emissions
EN 55022
Class A
ESD
EN 61000-4-2 Criteria A; ±8 kV Air ±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
See Note 3 EN 61000-4-4
Criteria A; ±2 kV
Surge
See Note 3 EN 61000-4-5
Criteria A; ±1 kV
CS
EN 61000-4-6
Criteria A; 10V/m
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+100
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
Reliability Specifications
0.45 Oz (12.8g)
Parameter
Conditions
Min. Typ. Max. Units
MTBF
Absolute Maximum Ratings
MIL HDBK 217F, 25°C, Gnd Benign 1.0
MHours
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com