English
Language : 

MA600MHI Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – MA600MHI SERIES
MA600MHI Series
High Isolation, 6W
Medical Approved
DC/DC Converters
Key Features:
• 6W Output Power
• 4 kVAC rms Isolation
• Reinforced Insulation
• 2 µA Leakage Current Max
• Wide 2:1 Input Range
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022
• 700 kH MTBF
• EN 60950 Approved
• EN 60601 Approved
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input 7.0 8.0 9.0
Input Start Voltage
24 VDC Input 13.0 15.0 18.0
VDC
48 VDC Input 30.0 33.0 36.0
12 VDC Input
8.5
Under Voltage Shutdown
24 VDC Input
16.0
VDC
48 VDC Input
34.0
Input Filter
␲ (Pi) Filter (Complies with EN55022 Class A)
Leakage Current
240 VAC, 60 Hz
2
µA
Short Circuit Input Power
3,000
mW
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±0.5 ±1.0
%
Output Voltage Balance
Dual Output , Balanced Loads
±0.5 ±2.0
%
Line Regulation
Vin = Min to Max
±0.3 ±0.5
%
Load Regulation
Iout = 25% to 100%
±0.5 ±1.0
%
Ripple & Noise (20 MHz), See Note 1
5V Output
All Other Outputs
75
100
100
150
mV P - P
Ripple & Noise (20 MHz)
Over Line, Load & Temp.
180 mV P - P
Ripple & Noise (20 MHz)
25 mV rms
Output Power Protection
120
%
Transient Recovery Time, See Note 2
Transient Response Deviation
25% Load Step Change
300 500
±3.0 ±6.0
µSec
%
Temperature Coefficient
±0.02 ±0.05 %/ºC
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage, Rated
60 Seconds 4,000
VAC rms
Isolation Test Voltage
Flash Tested For 1 Sec 6,000
VPk
Reinforced Insulation Working Voltage
300
VAC
Isolation Resistance
500 VDC 1,000
M⍀
Isolation Capacitance
100 kHz, 1V
7
13
pF
Switching Frequency
150
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+75
ºC
Operating Temperature Range
Case -40
+95
ºC
Storage Temperature Range
-50
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.25 x 0.80 x 0.47 Inches (31.8 x 20.3 x 12.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.63 Oz (18.0g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign 700
kHours
Safety Approvals
UL 60601, UL 60950, EN 60601, EN 60950
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
25.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case For 10 Sec
260
ºC
Internal Power Dissipation
All Models
2,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com