English
Language : 

LDC-80 Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – 90W Output Power
LDC-80 Series
Compact, LED, 90W
Constant Current
AC/DC Power Supply
Key Features:
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 90W Output Power
• UL 8750 Approved
• Constant Current Output
• Active PFC
• 90 - 305 VAC Input
• IP65 / IP67 Rated
• Meets EN 55015, EN 61547
• Dimming Function
• >50 kHour Life Expectancy
• Lightning Surge Protection
• Over Volt/Temp Protection
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
90
305
VAC
127
431
VDC
Input Frequency
47
63
Hz
Inrush Current, See Note 1
230 VAC
75
A Pk
115 VAC
1.10
Input Current
230 VAC
0.55
A
264 VAC
0.50
0.98 @ 115 VAC
Power Factor Correction
0.96 @ 230 VAC
0.94 @ 264 VAC
Total Harmonic Distortion (THD)
See Note 2
20
%
Turn On Delay, See Note 3
115 VAC
1.0
230 VAC
0.5
S
Leakage Current
277 VAC
0.75
mA
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Current Accuracy
±5.0
%
Line Regulation
VIN = Min to Max
±1.0
%
Ripple & Noise (20 MHz)
See Note 4
1.0
V P-P
Output Ripple Current
±5.0
%
Hold-Up Time
115 VAC 16.0
mS
Over Temperature Protection
±10%, Autorecovery
85
°C
Short Circuit Protection, See Note 5
Continuous
Overload Protection
Autorecovery 95
107
%IOUT
General
Parameter
Conditions
Min. Typ. Max. Units
Input to Output 3,750
Isolation Voltage, 60S
Input to FG 2,000
VAC
Output to FG 500
Input to Output
Insulation Resistance
Input to FG 100 M⍀ / 500 VDC / 25°C / 70% RH
Output to FG
EMI Characteristics
Parameter
Standard
EMI
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EMS
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
Surge
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +70
°C
Storage Temperature Range
-40
+85
°C
Cooling
Free Air Convection (See Derating Curve on Page 2)
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagrams (Page 4)
Weight
32.1 Oz (950g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 220
kHours
Life Expectancy
See Note 6 50
kHours
Safety Standards
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
Vibration
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
www.micropowerdirect.com