LCP100E Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – LCP100E SERIES | |||
|
LCP100E Series
Low Cost, 1W
Miniature SMT
DC/DC Converters
Key Features:
Electrical Speciï¬cations
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
⢠1W Output Power
Parameter
Conditions
Min. Typ. Max. Units
⢠Miniature SMT Case
Input Voltage Range
⢠DCP01 Series Replacement
5 VDC Input 4.50 5.0 5.50
12 VDC Input 10.80 12.0 13.20
VDC
⢠1,500 VDC Isolation
Input Filter
Internal Capacitor
⢠Short Circuit Protected
Output
⢠>3.5 MHour MTBF
⢠DIP Ver Available (ACP100E)
⢠LOW, LOW COST!!
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Conditions
Min. Typ.
±3.0
For Vin Change of 1%
See Model Selection Guide
Max.
±1.2
Units
%
%
Ripple & Noise (20 MHz), See Note 3
50% Iout
100% Iout
20
mV P - P
50 75
Temperature Coefï¬cient
±0.03 %/°C
Output Short Circuit, See Note 4
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
Mï
Isolation Capacitance
100 kHz, 1V
25
pF
Switching Frequency
100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+100
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
0.77 x 0.42 x 0.18 Inches (19.5 x 10.53 x 4.5 mm)
Case Material
Non-Conductive Black Plastic (UL-94V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Speciï¬cations
Parameter
MTBF
Shock & Vibration, See Note 5
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
0.05 Oz (1.4g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min. Typ. Max. Units
3.5
MHours
Meets MIL-STD-202F, IEC68-2-6
Conditions
Min. Typ. Max.
5 VDC Input -0.7
9.0
12 VDC Input -0.7
18.0
Units
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
260
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |