Isolated N-Channel
IGBT Driver
Electrical Specifications
Key Features:
Absolute Maximum Ratings, TA = 25 ºC unless otherwise noted.
• Internal OptoCoupler
Parameter
Conditions
Min. Typ.
• 30 kV/µS CMR
VCC
• VISO = 3,750V
Supply Voltage
VEE
DC
• Two Supply Drive Topology
• TTL Compatible Input
• Short Circuit Protected
• Fault Signal Output
• Switching Freq. to 20 kHz
• Compatible With M57962AL
Input Voltage
Input Current
Output Voltage
Output Current
VIN
IIN
VO
IGON
IGOFF
See Note 3
See Note 4
When Output is “H”
Pulse Width 2µS, Frequency Ϲ 20 kHz
Isolation Voltage
VISO Sine Wave Voltage 50 Hz/ 60 Hz , 1 Min
Junction Temperature
TJ
Recommended For:
• 600V Series IGBT (up to 600A)
• 1200V Series IGBT (up to 400A)
• 1700V Series IGBT (up to 200A)
Operating Temperature
TOP
-20
Storage Temperature
TST
-40
Fault Output Current
IFO
See Note 5
Electrical Characteristics, TA = 25 ºC, VCC = 15 VDC, VEE = -10 VDC unless otherwise noted.
Parameter
Conditions
Min. Typ.
VCC
Supply Voltage
VEE
Switching Frequency
f
14 15
Recommended Range
-7
Recommended Range 0
Gate Resistor
RG
2
Input CMR
15 30
“H” Input Current
IIH
Recommended Range 10 16
“H” Output Voltage
VOH
13 14
“L” Output Voltage
VOL
-6
“L-H” Propagation
TPLH
Operates With
“L-H” Rise Time
TR
IG100 Series
DC/DC Converters “H-L” Propagation
TPHL
“H-L” Fall Time
TF
IIH = 16 mA
0.5
IIH = 16 mA
0.6
IIH = 16 mA
1.0
IIH = 16 mA
0.4
Protection Reset Time
TTIMER
1.0 1.3
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Fault Output Current
Controlled Time Detect
Soft Turn-On Time
IFO
TTRIP1
TTRIP2
TOFF2
See Note 6
5.0
Short Circuit 1, See Note 7
2.6
Short Circuit 2, See Note 8
3.0
See Note 9
5.0
SC Detect Voltage
VSC
Collector Voltage of Module 15
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Notes:
1. Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
2. ”H” = high level signal. “L” = low level signal.
3. The voltage applied to pin 1.
4. The voltage measured between pins 13 and 14.
5. The input current at pin 8.
6. The input current at pin 8. R2 = 4.7 k⍀.
7. Pin 1 м 15 VDC. Pin 2 open.
8. Pin 1 м 15 VDC. A 1,000 pF connected from pin 2 to pin 4.
9. Pin 1 м 15 VDC.
www.micropowerdirect.com
Max.
18
-15
50
25
VCC
+5.0
-5.0
3,750
150
+70
+125
20
Max.
-10
20
20
-9
1.0
1.0
1.3
1.0
2.0
Units
VDC
VDC
mA
VDC
A
VAC
ºC
ºC
ºC
mA
Units
VDC
kHz
⍀
kV/µS
mA
VDC
VDC
µS
µS
µS
µS
mS
mA
µS
µS
µS
VDC