English
Language : 

IGD841 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Hybrid Integrated Isolated N-Channel IGBT Driver
IGD841
Hybrid Integrated
Isolated N-Channel
IGBT Driver
Electrical Specifications
Key Features:
Absolute Maximum Ratings, TA = 25 ºC unless otherwise noted.
• Internal OptoCoupler
Parameter
Conditions
Min. Typ. Max.
• 30 kV/µS CMR
Supply Voltage
VCC
DC
25
• VISO = 3,750V
Input Voltage
VIN
See Note 3
50
• One Supply Drive Topology
Input Current
IIN
• Compact SIP Package
See Note 4
25
• Short Circuit Protected
Output Current
IGON
Pulse Width 2µS, Frequency Ϲ 20 kHz
+5.0
• Fault Signal Output
IGOFF
-5.0
• Switching Freq. to 20 kHz Isolation Voltage
VISO Sine Wave Voltage 50 Hz/ 60 Hz , 1 Min
3,750
• Compatible With EXB841 Junction Temperature
TJ
150
Operating Temperature
TOP
-20
+70
Recommended For: Storage Temperature
TST
-40
+125
• 600V Series IGBT (up to 600A) Fault Output Current
IFO
See Note 5
20
• 1200V Series IGBT (up to 400A) Electrical Characteristics, TA = 25 ºC, VCC = 15 VDC unless otherwise noted.
• 1700V Series IGBT (up to 200A)
Parameter
Conditions
Min. Typ. Max.
Supply Voltage
VCC
Recommended Range 14 15
Reverse Bias Supply Voltage VRB
Recommended Range
-5
Switching Frequency
f
Recommended Range 0
20
Gate Resistor
RG
2
Input CMR
15 30
“H” Input Current
IIH
Recommended Range 10 16 20
“H” Output Voltage
VOH
VCC = 20V
14
“L” Output Voltage
VOL
VCC = 20V
-5
“L-H” Propagation
TPLH
IIH = 16 mA
0.5 1.0
“L-H” Rise Time
TR
IIH = 16 mA
0.6 1.0
“H-L” Propagation
TPHL
IIH = 16 mA
1.0 1.3
“H-L” Fall Time
TF
IIH = 16 mA
0.4 1.0
Protection Threshold Voltage VOCP
VCC = 20V
8.5
Protection Reset Time
TTIMER
1.0 1.4 2.0
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Fault Output Current
Controlled Time Detect
Soft Turn-Off Time
SC Detect Voltage
IFO
TTRIP1
TOFF2
VSC
See Note 6
5.0
Short Circuit 1, See Note 7
2.6
See Note 8
5.0
Collector Voltage of Module 15
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Notes:
1. Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
2. ”H” = high level signal. “L” = low level signal.
3. The voltage applied to pin 15.
4. The current measured between pins 15 and 14.
5. The current at pin 5.
6. The current at pin 5. R2 = 4.7 k⍀.
7. Pin 6 м 15 VDC.
8. Pin 6 м 15 VDC.
Units
VDC
VDC
mA
A
VAC
ºC
ºC
ºC
mA
Units
VDC
VDC
kHz
⍀
kV/µS
mA
VDC
VDC
µS
µS
µS
µS
VDC
mS
mA
µS
µS
VDC
www.micropowerdirect.com