English
Language : 

G200 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Compact MiniDIP, 2W Single & Dual Output DC/DC Converters
MicroPower
Direct
Compact MiniDIP, 2W
Single & Dual Output
DC/DC Converters
G200 Series
Key Features
Miniature DIP Package
1.0 kVDC Isolation
2W Output Power
Single & Dual Outputs
3.6 MH MTBF
Low Cost
Electrical Specifications
Specifications typical @ +251C with nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
5 VDC Input 4.5 5.0 5.5
Input Voltage Range
12 VDC Input 10.8 12.0 13.2
24 VDC Input 21.6 24.0 26.4
VDC
48 VDC Input 43.2 48.0 52.8
Input Filter
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
!1.0 !3.0
%
Output Voltage Balance
Dual Output , Balanced Loads
!0.1 !1.0
%
Line Regulation
For Vin Change of 1%
!1.2 !1.5
%
Load Regulation
See Model Selection Guide
Ripple & Noise (20 MHz)
100 150 mV P - P
Ripple & Noise (20 MHz)
Over Line, Load & Temp.
200 mV P - P
Ripple & Noise (20 MHz)
5
mV rms
Output Power Protection
120
%
Temperature Coefficient
!0.01 !0.02 %/1C
Output Short Circuit
Momentary (0.5 Sec.)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,000
VDC
Isolation Resistance
500 VDC 1,000
MΩ
Isolation Capacitance
100 kHz, 1V
80 120
pF
Switching Frequency
50 80 100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Storage Temperature Range
-40 +25 +70
1C
-40
+125
1C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size, 5V, 12V & 24V Input Models
0.80 x 0.40 x 0.27 Inches (20.32 x 10.16 x 6.85 mm)
Case Size, 48VDC Input Models
0.80 x 0.40 x 0.30 Inches (20.32 x 10.16 x 7.50 mm)
Case Material
Non-Conductive Black Plastic
Weight
0.09 Oz (2.7g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 251C, Gnd Benign
3.6
MHours
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
5 VDC Input -0.7
9.0
Input Voltage Surge (1 Sec)
12 VDC Input -0.7
24 VDC Input -0.7
18.0
VDC
30.0
48 VDC Input -0.7
55.0
Internal Power Dissipation
All Models
650
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
MicroPower Direct TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com WEB: www/micropowerdirect.com