English
Language : 

F2500RU Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – 4:1 Input 25W - 30W Single & Dual Output DC/DC Converters
F2500RU Series
4:1 Input 25W - 30W
Single & Dual Output
DC/DC Converters
Key Features:
• 25W-30W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Meets EN55022 Class A
• Compact 2 x 1.6 In. Case
• Single & Dual Outputs
• Remote ON/OFF
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Start Voltage
24 VDC Input 9.4 9.7 10.0
48 VDC Input 17.0 17.5 18.0
VDC
Under Voltage Shutdown
24 VDC Input 9.0 9.3 9.5
48 VDC Input 16.0 16.5 17.0
VDC
Input Filter
␲ (Pi) Filter (Meets EN55022 Class “A”)
Reverse Polarity Input Current
2.0
A
Short Circuit Input Power
4,500
mW
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±0.5 ±1.0
%
Output Voltage Balance
Dual Output , Balanced Loads
±0.5 ±2.0
%
Line Regulation
For Vin Min to Max
±0.2 ±0.5
%
Load Regulation
Iout = 50% to 100%
±0.3 ±1.0
%
Ripple & Noise (20 MHz) (Note 1)
55 80 mV P - P
Ripple & Noise (20 MHz)
Over Line, Load & Temp.
100 mV P - P
Output Power Protection
120
180
%
Transient Recovery Time (Note 2)
Transient Response Deviation
25% Load Step Change
150 300
±2.0 ±4.0
µSec
%
Temperature Coefficient
±0.01 ±0.02 %/°C
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Voltage Test
Flash Tested For 1 Second 1,650
VDC
Isolation Resistance
500 VDC 1,000
M⍀
Isolation Capacitance
100 kHz, 1V
1,200 1,500
pF
Switching Frequency
290 330 360
kHz
Over Temperature Protection
Case Temperature 107 112 117
°C
Remote On/Off (Note 3)
Parameter
Conditions
Min. Typ. Max. Units
Supply On
2.5
100.0
VDC
Supply Off
-1.0
1.0
VDC
Standby Input Current
5
mA
Control Common
Referenced to Negative Input (pin 2)
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+50
°C
Operating Temperature Range
Case -40
+105
°C
Storage Temperature Range
-50
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
2.0 x 1.6 x 0.37 Inches (50.8 x 40.6 x 9.3 mm)
Case Material
Metal with Non-Conductive Base
Weight
1.75 Oz (48g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 1,000
kHours
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
48 VDC Input -0.7
50.0
100.0
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
260
°C
Internal Power Dissipation
All Models
5,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com