English
Language : 

DR-45 Datasheet, PDF (1/2 Pages) Total Power International – 45W Single Output Industrial DIN Rail Power Supply
DR-45 Series
Low Cost, Industrial
45W, DIN Rail Mount
AC/DC Power Supplies
New Industrial
Supplies!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 45W Output Power
Parameter
Input Voltage Range
Conditions
Min. Typ. Max.
85
264
120
370
Units
VAC
VDC
• DIN Rail Mountable
Input Frequency Range
47
63
Hz
• Universal AC Input
• UL 508 Approved
• Safety Approved
• 5, 12, 15 & 24 VDC Outputs
• Cond./Rad. EMI Class B
• >364 kH MTBF
• LOW COST!
Inrush Current
Leakage Current
Output
Parameter
Output Voltage Tolerance
Voltage Adjustment Range
230 VAC, Cold Start
115 VAC, Cold Start
240 VAC
56
28
1.0
Conditions
Min. Typ. Max.
Note 1
±1.0
5 VDC Output 4.75
5.5
12 VDC Output 10.8
13.2
15 VDC Output 13.5
16.5
A
mA
Units
%
VDC
48 VDC Output 21.6
26.4
Line Regulation
±1.0
%
Load Regulation
Iout = 10% to 100%
±1.0
%
Set Up Time
230 VAC, Full Load
800
mSec
Rise Time
At Full Load
60
mSec
Hold Time
230 VAC, Full Load
100
mSec
5 VDC Output
100
Ripple & Noise (Note 2)
12 VDC Output
15 VDC Output
200
240
mV Pk-Pk
24 VDC Output
480
Output Power Protection
Note 3 105
150
%
5 VDC Output 5.75
6.75
Over Voltage Protection (Note 4)
12 VDC Output 13.8
15 VDC Output 17.25
16.2
20.25
VDC
24 VDC Output 27.6
32.4
Over Temperature Protection
Note 5
135
ºC
Temperature Coefficient
0ºC to 50ºC
±0.03
%/ºC
Switching Frequency
Fixed
100
kHz
General
Parameter
Conditions
Min. Typ. Max. Units
Input - Output 3,000
RoHS Compliant Isolation Voltage
Input - FG (Frame Ground) 1,500
VAC
Output - FG (Frame Ground) 500
Isolation Resistance (Note 6)
500 VDC 100
MΩ
MicroPower Direct Environmental
232 Tosca Drive
Parameter
Conditions
Min. Typ. Max. Units
Stoughton, MA 02072
Operating Temperature Range
Ambient -10 +25 +50
ºC
USA
Storage Temperature Range
-20
+85
ºC
Operating Humidity
RH, Non-condensing 20
90
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Storage Humidity
Vibration
Physical
Case Size
RH, Non-condensing 10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
3.66 x 3.05 x 2.64 Inches (93.0 x 78.0 x 67.0 mm)
Case Material
Plastic (UL94-V0)
Connection
Screw Terminal
Weight
11 Oz (0.31 kg)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign 364.6
kHours
Safety Standards
UL 508, UL 60950, EN 60950-1
Safety Approvals
UL, cUL, TUV
EMI Compliance
Compliance to EN55011, EN55022 (CISPR22) Class B
Harmonic Current Compliance
Compliance to EN6100-3-2,-3
EMS Immunity Compliance
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A