Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
24 VDC Input 9.0 24.0 36.0
48 VDC Input 18.0 48.0 72.0
VDC
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0 ±3.0
%
Output Voltage Balance
±1.0 ±2.0
%
Line Regulation
Vin = Min to Max
±0.2 ±0.75
%
Load Regulation
Iout = 10% to 100%
±0.5 ±1.5
%
Ripple And Noise (20 MHz)
See Note 1
50 100 mV P - P
Temperature Coefficient
±0.03 %/°C
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz, 1V
80
pF
Switching Frequency
Iout = 100%
300
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.02 x 0.37 x 0.49 Inches (26.0 x 9.50 x 12.50 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
0.24 Oz (7.0g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Units
MHours
Conditions
Min. Typ. Max.
24 VDC Input -0.7
40.0
48 VDC Input -0.7
80.0
Units
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.