English
Language : 

B3000RW_14 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – B3000RW SERIES
B3000RW Series
Compact 1 x 2 Inch 30W
Wide Input Range
DC/DC Converters
Key Features:
• 30W Output Power
• Compact 1 x 2 Inch Case
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Optional Remote ON/OFF
• Overvoltage Protection
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Start Voltage
Conditions
Min. Typ. Max.
24 VDC Input 17.0 17.5 18.0
48 VDC Input 34.0 35.0 36.0
Units
VDC
Input Undervoltage Shutdown
Input Overvoltage Shutdown
Input Filter, See Note 1
Reverse Polarity Input Current
Short Circuit Input Power
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, 2.5, 3.3, 5 Vout
Load Regulation, 12, 15 Vout
Ripple & Noise (20 MHz), See Note 2
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
24 VDC Input 16.0
48 VDC Input 32.0
24 VDC Input 40.0
48 VDC Input 80.0
␲ (Pi) Filter
16.5 17.0
33.0 34.0
42.0 44.0
82.0 84.0
2.0
4,500
VDC
VDC
A
mW
Conditions
Min. Typ. Max. Units
±0.5 ±1.0
%
Vin = Min to Max
±0.1 ±0.3
%
Iout = 0% to 100%
±0.5 ±1.0
%
Iout = 10% to 100%
±0.5 ±1.0
%
75 100 mV P - P
Over Line, Load & Temp.
120 mV P - P
10 mV rms
110
160
%
25% Load Step Change
200 500
±2.0 ±5.0
µSec
%
Temperature Coefficient
Output Short Circuit
General
Parameter
Conditions
±0.01 ±0.02
Continuous
Min. Typ. Max.
%/°C
Units
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
60 Seconds
Flash Tested For 1 Sec
500 VDC
100 kHz, 1V
1,500
1,650
1,000
1,200
1,500
VDC
VDC
M⍀
pF
Switching Frequency
Remote On/Off See Note 4
Parameter
Conditions
280 350 400
Min. Typ. Max.
kHz
Units
Supply On
2.5
100.0
VDC
Supply Off
Standby Input Current
Control Common
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Conditions
-1.0
1.0
VDC
5
mA
Referenced to Negative Input (pin 2)
Min. Typ. Max.
Ambient -40 +25 +50
Case
+105
-50
+125
Units
°C
°C
°C
Cooling
Humidity
RFI
Physical
Free Air Convection
RH, Non-condensing
95
%
Six-Side Shielded Metal Case
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Metal with Non-Conductive Base (Anodized Black Aluminum)
1.13 Oz (32g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 600
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ. Max.
50.0
100.0
260.0
Units
VDC
°C
Internal Power Dissipation
All Models
5,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com