B1000R Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – 10W, 5 VDC Input Compact, Dual Output DC/DC Converters | |||
|
MicroPower
Direct
10W, 5 VDC Input
Compact, Dual Output
DC/DC Converters
B1000R Series
Key Features
5 VDC Input
1500 VDC Isolation
10W Output Power
Tightly Regulated Dual Outputs
Meets EN55022 Class âAâ
Low Cost
Electrical Speciï¬cations
Speciï¬cations typical @ +251C with nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
4.5 5.0 5.5
VDC
Input Filter
Ï (Pi) Filter (Complies with EN55022 Class A)
Reverse Polarity Input Current
2.0
A
Short Circuit Input Power
3,500 4,500
mW
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
!0.5 !1.0
%
Output Voltage Balance
Dual Output , Balanced Loads
!0.2 !0.5
%
Line Regulation
Vin = Min to Max
!0.1
%
Load Regulation
Iout = 10% to 100%
!0.15
%
Ripple & Noise (20 MHz)
20 30 mV P - P
Output Power Protection
150
%
Transient Recovery Time (Note 1)
Transient Response Deviation
25% Load Step Change
200
µSec
!4.0
%
Temperature Coefï¬cient
!0.01 !0.02 %/1C
Output Short Circuit
Continuous
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
Mâ¦
Isolation Capacitance
100 kHz, 1V
500 600
pF
Switching Frequency
270 280 290
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
-40 +25 +71
1C
Storage Temperature Range
-40
+125
1C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
RFI
Six-Sided Shielded, Metal Case
Conducted EMI
EN55022 Class A
Physical
Case Size
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Case Material
Metal with Non-Conductive Base
Weight
1.06 Oz (30g)
Reliability Speciï¬cations
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 251C, Gnd Benign
700
kHours
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Surge (1 Sec)
-0.7
7.5
VDC
Internal Power Dissipation
5,000
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
MicroPower Direct TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com WEB: www/micropowerdirect.com
|
▷ |