Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 1W Output Power
Parameter
Conditions
Min. Typ. Max. Units
• Miniature Low Profile Case
• DCP01 Series Replacement
• 1,500 VDC Isolation
• Short Circuit Protected
• >3.5 MHour MTBF
• SMT Ver Available (LCP100E)
• LOW, LOW COST!!
Input Voltage Range
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
5 VDC Input 4.50 5.0
12 VDC Input 10.80 12.0
Internal Capacitor
5.50
13.20
VDC
Conditions
Min. Typ.
±3.0
For Vin Change of 1%
See Model Selection Guide
Max.
±1.2
Units
%
%
Ripple & Noise (20 MHz), See Note 3
50% Iout
100% Iout
20
mV P - P
50 75
Temperature Coefficient
±0.03 %/°C
Output Short Circuit, See Note 4
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz, 1V
25
pF
Switching Frequency
100
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+100
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
0.77 x 0.30 x 0.18 Inches (19.5 x 7.62 x 4.5 mm)
Case Material
Non-Conductive Black Plastic (UL-94V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
MTBF
Shock & Vibration, See Note 5
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
0.05 Oz (1.4g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min. Typ. Max. Units
3.5
MHours
Meets MIL-STD-202F, IEC68-2-6
Conditions
Min. Typ. Max.
5 VDC Input -0.7
9.0
12 VDC Input -0.7
18.0
Units
VDC
Lead Temperature
1.5 mm From Case For 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com