A1500RWSeries
2:1 Input Range, 15W
Single & Dual Output
DC/DC Converters
Key Features:
• 15W Output Power
• 2:1 Input Voltage Range
• Compact DIP Case
• 1,600 VDC I/O Isolation
• Meets EN 55022 “A”
• Single & Dual Outputs
• 37.5 W/IN3 Power Density
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input 9.0 12.0 18.0
Input Voltage Range
24 VDC Input 18.0 24.0 36.0
VDC
48 VDC Input 36.0 48.0 75.0
Input Filter
␲ (Pi) Filter (Meets EN 55022 Class “A”)
Input Reflected Ripple Current
20.0
mA P - P
Output
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0
%
Line Regulation, VIN = Min to Max
Single Output
Dual Output
±0.2
±0.5
%
Load Regulation, IOUT = 0% to 100%
Single Output
Dual Output
±0.5
±1.0
%
Cross Regulation, Dual Output
See Note 1
±5.0
%
Ripple & Noise (20 MHz)
See Note 2
60 mV P - P
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
150
25% Load Step Change
250
±3.0
% IOUT
µSec
%
Temperature Coefficient
±0.02
%/ºC
Output Short Circuit Protection
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage (Input/Output)
Isolation Voltage (Case/Input, Output)
Isolation Resistance
3 Seconds 1,600
3 Seconds 1,600
500 VDC 1,000
VDC
M⍀
Isolation Capacitance
100 kHz/1V
2,000
pF
Switching Frequency
250
330
kHz
EMI Characteristics
Parameter
Standard
Level
Radiated Emissions
EN 55022
Class A
Conducted Emissions
EN 55022
Class A
ESD
EN 61000-4-2
Criteria B
RS
EN 61000-4-3
Criteria A
EFT, See Note 4
EN 61000-4-4
Criteria B
Surge, See Note 4
EN 61000-4-5
Criteria B
CS
EN 61000-4-6
Criteria A
PFMF
EN 61000-4-8
Criteria A
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+85
ºC
Operating Temperature Range
Case
+105
ºC
Storage Temperature Range
-40
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Case Material
Metal with Non-Conductive Base (UL94V-0)
Weight
0.705 Oz (20g)
Reliability Specifications
Parameter
Conditions
Min. Typ. Max. Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign 460
kHours
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max. Units
12 VDC Input -0.7
36.0
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case For 10 Sec
260
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.