A1500RU Series
4:1 Input Range, 15W
Single & Dual Output
DC/DC Converters
Key Features:
• 15W Output Power
• 4:1 Input Voltage Range
• Compact DIP Case
• 1,600 VDC I/O Isolation
• Meets EN 55022 “A”
• Single & Dual Outputs
• 37.5 W/IN3 Power Density
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Filter
Input Reflected Ripple Current
Output
Parameter
Output Voltage Accuracy
Line Regulation, VIN = Min to Max
Load Regulation, IOUT = 0% to 100%
Cross Regulation, Dual Output
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit Protection
General
Conditions
Min. Typ. Max.
24 VDC Input 9.0 24.0 36.0
48 VDC Input 18.0 48.0 75.0
␲ (Pi) Filter (Meets EN 55022 Class “A”)
20.0
Units
VDC
mA P - P
Conditions
Min. Typ.
±1.0
Single Output
Dual Output
Single Output
Dual Output
See Note 1
See Note 2
150
25% Load Step Change
250
±3.0
±0.02
Continuous (Autorecovery)
Max.
±0.2
±0.5
±0.5
±1.0
±5.0
60
Units
%
%
%
%
mV P - P
% IOUT
µSec
%
%/ºC
Parameter
Isolation Voltage (Input/Output)
Isolation Voltage (Case/Input, Output)
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Note 4
Surge, See Note 4
CS
PFMF
Environmental
Conditions
3 Seconds
3 Seconds
500 VDC
100 kHz/1V
Min.
1,600
1,600
1,000
250
Typ.
2,000
Max.
330
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Level
Class A
Class A
Criteria B
Criteria A
Criteria B
Criteria B
Criteria A
Criteria A
Units
VDC
M⍀
pF
kHz
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Ambient -40
+85
ºC
Case
+105
ºC
-40
+125
ºC
Free Air Convection
RH, Non-condensing
95
%
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base (UL94V-0)
0.705 Oz (20g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25ºC, Gnd Benign 410
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ. Max.
50.0
100.0
260
Units
VDC
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.