English
Language : 

A100EHI_14 Datasheet, PDF (1/2 Pages) MicroPower Direct, LLC – Low Cost, Miniature DIP 1W, Very High Isolation DC/DC Con vert ers
A100EHI Series
Low Cost, Miniature DIP
1W, Very High Isolation
DC/DC Converters
Key Features:
• 1W Output Power
• 6,000 VDC Isolation
• EN 60950 Approved (UL)
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
Input Voltage Range
5 VDC Input 4.5 5.0 5.5
12 VDC Input 10.8 12.0 13.2
VDC
Input Filter
Internal Capacitor
• -40ºC to 85ºC Operation Short Circuit Input Power
1,500
mW
• 24 Pin DIP Case
Output
• 5V and 12V Inputs
• Single & Dual Outputs
• 16 Standard Models
• 3.5 MH MTBF
• LOWEST COST!!
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, 5V Input
Load Regulation, 12V Input
Conditions
Min. Typ. Max.
±2.0 ±4.0
Dual Output , Balanced Loads
±1.0 ±3.0
For Vin Change of 1%
±1.2
Iout = 10% to 100%
±15
Iout = 10% to 100%
±10
Units
%
%
%/%
%
%
Ripple & Noise (20 MHz)
See Note 1
75 150 mV P - P
Output Power Protection
120
%
Temperature Coefficient
±0.01 ±0.03 %/ºC
Output Short Circuit
Momentary (1.0 Seconds)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 6,000
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz, 1V
2
pF
Switching Frequency
250
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40
+85
ºC
Storage Temperature Range
-55
+125
ºC
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.27 x 0.62 x 0.40 Inches (32.3 x 15.7 x 10.2 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.42 Oz (12g)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
Min. Typ.
MIL HDBK 217F, 25ºC, Gnd Benign 3.5
UL 60950, EN 60950
UL, cUL; File No. E245422
Max.
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Conditions
Min. Typ. Max.
5 VDC Input -0.7
7.5
12 VDC Input -0.7
15.0
Units
VDC
Lead Temperature
1.5 mm From Case For 10 Sec.
300
ºC
Internal Power Dissipation
All Models
1,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com