MC33388
DEVICE DESCRIPTION
Figure 3. State Machine And Operation Modes
Normal mode (1, 1)
(BUS failure, ON)
(0, 1)
(1, 1)
Go to sleep mode (0, 1)
(Wake up event, OFF3)
(1, 1)
(1, 1)
(1, 0)
(0, 0)
(1, 1)1
Sleep mode (0, 0)
(1, 0)
(0, 1)
Receive Only mode (1, 0)
(0, 0)
(0, 0)4
(1, 0)1
(Wake up event1,2, OFF)
(0, 0)
(0, 1)
Stand-by VBAT mode (0, 0)
wake-up event
(bus message, wake pin)
(VBAT fail flag, ON)
(1, 0)
(Wake up event, ON)
Legend:
Transceiver mode (STB state, EN state)
(NERR function, INH state)
power up
NERR: BUS - Bus error is flagged
WAKE - Wake-up event is flagged
BAT - BAT fail is flagged
INH: ON - INH is switched on
OFF - INH is floating
1 with permanent VDD
2 VDD is still switched on
3 if no wake-up occurs after 25µs
4 as long as INH is on
Table 1 • Truth Table
STB EN
Mode
INH
NERR
RX
RTL
IDD (4)
IBAT (4)
0
0
0
0
VBAT
Standby1
Sleep2
High
Floating
Active LOW:
wake-up interrupt signal
(if VDD is present)
Switched to
VBAT
Switched to
VBAT
5µA
Not
applicable
typ. 15µA
typ. 15µA
0
1
Go to sleep Floating
command
Switched to
VBAT
1
0 Receive Only3
High
Active LOW:
Switched to
800µA
VBAT power-on flag High: recessive state
VDD
Low: dominant state
1
1
Normal
High
Active LOW:
Switched to 2.3mA (5)
typ.
error flag
VDD
3.3mA (6)
150µA
NOTES:
1. Wake-up interrupts are released when entering normal operating mode.
2. If go to sleep command was used before (EN may turn LOW as VDD drops, without affecting internal functions because of fail safe functionality.
3. VBAT power-on flag will be reset when entering normal operation mode.
4. Value are typical, without bus load current.
5. In recessive state.
6. In Dominant State, value with no load at bus.
MC33388
MOTOROLA
9