English
Language : 

MC74LVQ574 Datasheet, PDF (3/8 Pages) Motorola, Inc – LOW-VOLTAGE CMOS OCTAL D-TYPE FLIP-FLOP
MC74LVQ574
ABSOLUTE MAXIMUM RATINGS*
Symbol
Parameter
Value
Condition
Unit
VCC
DC Supply Voltage
–0.5 to +7.0
V
VI
DC Input Voltage
–0.5 ≤ VI ≤ VCC + 0.5V
V
VO
DC Output Voltage
–0.5 ≤ VO ≤ VCC + 0.5
Output in HIGH or LOW State
V
IIK
DC Input Diode Current
–20
VI = –0.5V
mA
+20
VI = VCC + 0.5V
mA
IOK
DC Output Diode Current
–20
VO = –0.5V
mA
+20
VI = VCC + 0.5V
mA
IO
DC Output Source/Sink Current
±50
mA
ICC
DC Supply Current
±400
mA
IGND
DC Ground Current
±400
mA
TSTG
Storage Temperature Range
–65 to +150
°C
* Absolute maximum continuous ratings are those values beyond which damage to the device may occur. Exposure to these conditions or
conditions beyond those indicated may adversely affect device reliability. Functional operation under absolute–maximum–rated conditions is
not implied.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
VCC
VI
VO
TA
∆V/∆t
Supply Voltage
2.0
Input Voltage
0
Output Voltage
0
Operating Free–Air Temperature
–40
Input Transition Rise or Fall Rate, VIN from 0.8V to 2.0V, VCC = 3.0V
0
Typ
Max
Unit
3.3
3.6
V
VCC
V
VCC
V
+85
°C
125
mV/ns
DC ELECTRICAL CHARACTERISTICS
TA = –40°C to +85°C
Symbol
Characteristic
Condition
Min
Max
Unit
VIH
HIGH Level Input Voltage (Note 1)
VIL
LOW Level Input Voltage (Note 1)
2.7V ≤ VCC ≤ 3.6V,
VO = 0.1V or VCC – 0.1V
2.7V ≤ VCC ≤ 3.6V,
VO = 0.1V or VCC – 0.1V
2.0
V
0.8
V
VOH
HIGH Level Output Voltage
2.7V ≤ VCC ≤ 3.6V; IOH = –50µA
VCC – 0.1
V
VCC = 2.7V; IOH = –12mA
2.2
VCC = 3.0V; IOH = –12mA
2.48
VOL
LOW Level Output Voltage
2.7V ≤ VCC ≤ 3.6V; IOL = 50µA
0.1
V
2.7V ≤ VCC ≤ 3.6V; IOL= 12mA
0.4
II
Input Leakage Current
2.7V ≤ VCC ≤3.6V; VI= VCC, GND
±1.0
µA
IOZ
Maximum 3–State Leakage Current
VI(OE) = VIL, VIH; VI, VO= VCC, GND
±2.5
µA
IOLD
Minimum Dynamic Output Current (Note 2)
VCC = 3.6V; VOLD = 0.8V Max
36
mA
IOHD
VCC = 3.6V; VOHD = 2.0V Min
–25
mA
ICC
Quiescent Supply Current
2.7V ≤ VCC ≤3.6V; VI = VCC, GND
10
µA
1. These values of VI are used to test DC electrical characteristics only. Functional test should use VIH ≥ 2.4V, VIL ≤ 0.5V.
2. Incident wave switching on transmission lines with impedances as low as 75Ω for commercial temperature range is guaranteed. Maximum test
duration is 2ms, one output loaded at a time.
ECLinPS and ECLinPS Lite
3
DL140 — Rev 3
MOTOROLA