MC145192EVK Datasheet, PDF (22/48 Pages) Motorola, Inc – Evaluation Board Manual | |||
|
◁ |
Screen #10 After [N] & [2] Commands Selected
This is the resulting screen that is displayed after the user selects the â[N] Change C Registerâ and then
the â[2] Change PDout Currentâ command. The user is provided a submenu to select from. This submenu
contains commands to change the PDout current settings.
The screen is slightly different depending on whether Output A is defined as a port or not. See command
[E] from the main menu.
Output A is configured as a port.
The current PDout setting is displayed as â70%â, â80%â, â90%â, or â100%â.
The user can select the [0], [1], [2], and [3] menu options to change the percent of PDout current.
If the [Q] command is selected, then the user is returned to the main menu. See screen #2.
Welcome to MC145xxx EVK Demonstration Program, rev 2.5
Change C Register, PDout Current
Available Boards â Current target board is: A, MC145190
Brd [A]!: MC145190
Brd [â]!: N/A
Brd [â]!: N/A
ââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââââ
When Output A is set to Port, Current range is 70 â 100%.
When Output A is NOT set to Port, Current range depends upon PDout Current Step Size.
When PDout Current Step Size is set to 10%, current range is 70 â 100%.
When PDout Current Step Size is set to 25%, current range is 25 â 100%.
Output A is currently defined as Port.
Change C Register, PDout Current â Currently: 100%
[0]! 70%
[1]! 80%
[2]! 90%
[3]! 100%
[Q] to return to previous menu
[X]! Terminate demonstration program. [?]! View help screen.
MC145192EVK ⢠MC145202EVK
22
MOTOROLA
|
▷ |