ABSOLUTE MAXIMUM RATINGS*
Symbol
Parameter
Value
Condition
Unit
VCC
VI
VO
IIK
IOK
IO
ICC
IGND
TSTG
DC Supply Voltage
DC Input Voltage
DC Output Voltage
DC Input Diode Current
DC Output Diode Current
DC Output Source/Sink Current
DC Supply Current
DC Ground Current
Storage Temperature Range
–0.5 to +7.0
V
–0.5 ≤ VI ≤ VCC + 0.5V
V
–0.5 ≤ VO ≤ VCC + 0.5
Output in HIGH or LOW State
V
–20
VI = –0.5V
mA
+20
VI = VCC + 0.5V
mA
–20
VO = –0.5V
mA
+20
VI = VCC + 0.5V
mA
±50
mA
±200
mA
±200
mA
–65 to +150
°C
* Absolute maximum continuous ratings are those values beyond which damage to the device may occur. Exposure to these conditions or
conditions beyond those indicated may adversely affect device reliability. Functional operation under absolute–maximum–rated conditions is
not implied.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
VCC
VI
VO
TA
∆V/∆t
Supply Voltage
2.0
Input Voltage
0
Output Voltage
0
Operating Free–Air Temperature
–40
Input Transition Rise or Fall Rate, VIN from 0.8V to 2.0V, VCC = 3.0V
0
Typ
Max
Unit
3.3
3.6
V
VCC
V
VCC
V
+85
°C
125
mV/ns
DC ELECTRICAL CHARACTERISTICS
Symbol
Characteristic
Condition
TA = –40°C to +85°C
Min
Max
Unit
VIH
VIL
VOH
HIGH Level Input Voltage (Note 1)
LOW Level Input Voltage (Note 1)
HIGH Level Output Voltage
VOL
LOW Level Output Voltage
II
IOLD
IOHD
ICC
Input Leakage Current
Minimum Dynamic Output Current (Note 2)
Quiescent Supply Current
2.7V ≤ VCC ≤ 3.6V,
2.0
V
VO = 0.1V or VCC – 0.1V
2.7V ≤ VCC ≤ 3.6V,
VO = 0.1V or VCC – 0.1V
0.8
V
2.7V ≤ VCC ≤ 3.6V; IOH = –50µA
VCC – 0.1
V
VCC = 2.7V; IOH = –12mA
2.2
VCC = 3.0V; IOH = –12mA
2.48
2.7V ≤ VCC ≤ 3.6V; IOL = 50µA
0.1
V
2.7V ≤ VCC ≤ 3.6V; IOL= 12mA
0.4
2.7V ≤ VCC ≤3.6V; VI= VCC, GND
±1.0
µA
VCC = 3.6V; VOLD = 0.8V Max
36
mA
VCC = 3.6V; VOHD = 2.0V Min
–25
mA
2.7V ≤ VCC ≤3.6V; VI = VCC, GND
10
µA
1. These values of VI are used to test DC electrical characteristics only. Functional test should use VIH ≥ 2.4V, VIL ≤ 0.5V.
2. Incident wave switching on transmission lines with impedances as low as 75Ω for commercial temperature range is guaranteed. Maximum test
duration is 2ms, one output loaded at a time.
MOTOROLA
2
LVQ DATA
BR1478