English
Language : 

WRA0505ZP-3WR2 Datasheet, PDF (5/6 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
WRA_ZP-3WR2 & WRB_ZP-3WR2 Series
Parameter description:
Model
FUSE
MOV
C0
C1
LDM1
C2
C3
CY1
Vin:5V
Vin:12V
Vin:24V
Vin:48V
Slow blown fuses according to the actual input current selections of the clients
--
S14K25
S14K35
S14K60
1000μF
1000μF
330μF/50V
330μF/100V
4.7μF/50V
4.7μF/100V
12μH
4.7μF/50V
4.7μF /100V
10μF
1nF/2KV
Note: ①.Part ① in the Fig. 3 is used for EMS test and part ② for EMI filtering, selected based on needs.
②.If there is no recommended parameters, the model no require the external component.
EMC solution-recommended circuit PCB layout
Dual
Single
Fig. 4
Note: Note: the min. distance of the bonding pads between input grounding and output grounding shall be ≥ 2mm.
4. Input current
When the electricity is provided by the unstable power supply, please make sure that the range of the output voltage fluctuation and the
ripple voltage of the power supply do not exceed the indicators of the modules. Input current of power supply should afford the flash startup
current of this kind of DC/DC module(see Fig. 5).
Generally: Vin=5V Iave =1400mA
Vin=12V Iave=620mA
Vin=24V Iave=310mA
Vin=48V Iave =150mA
Iave
Input Voltage
scope
Input Voltage (V)
Fig. 5
5. For more information please find DC-DC converter application notes on www.mornsun-power.com
2014.04.14-A/3
Page 5 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation