TEST CONFIGURATIONS
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
Oscilloscope
Lin
DC DC Current
Cin Probe
Load
Lin(4.7µH) Cin(220µF, ESR < 1.0Ω at 100 KHz)
DESIGN CONSIDERATIONS
1) Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum output load could not be less than 10% of the full
load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load, or
use our company’s products with a lower rated output power (A_S-1W / B_LS-1W Series).
2) Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is add a circuit
breaker to the circuit.
3) Recommended circuit
If you want to further decrease the input/output ripple, an capacitor filtering network may be connected to the input and output ends of the DC/DC
converter, see (Figure 3).
It should also be noted that the capacitance of filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every
channel of output, provided the safe and reliable operation is ensured, the recommended capacitance of its filter capacitor sees (Table 1).
Dual O utput
Vin
Cin
GND
Single Output
Vin
Cin
GND
DC DC
DC DC
(Figure 3)
+Vo
C out
0V
Cout
-Vo
+Vo
C out
0V
EXTERNAL CAPACITOR TABLE (TABLE 1)
Vin Cin Single Vout Cout
(VDC) (µF)
(VDC)
(µF)
Dual Cout#
Vout (µF)
(VDC)
3.3/5 4.7
3.3/5
10
±5 4.7
12 2.2
9
4.7
±9 2.2
15 2.2
12
2.2 ±12 1
24
1
15
1
±15 0.47
--
--
24
1
±24 0.47
Note: # For each output. It’s not recommended to connect any external capacitor in the
application field with less than 0.5 watt output.
4) Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear regulator and an capacitor filtering network
with overheat protection that is connected to the input or output end in series (Figure 4), the recommended capacitance of its filter capacitor sees
(Table 1), linear regulator based on the actual voltage and current to reasonable selection.
Dual Output
Vin
REG
REG
+Vo
GND
DC DC
0V
REG
-Vo
5) Cannot use in parallel and hot swap
Single Output
Vin
REG
REG
+Vo
DC DC
GND
0V
(Figure 4)
Not e:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed.
2. Max. Capacitive Load tested at input voltage range and full load.
3. All date in the datasheet are measured according to nominal input voltage, rated output load, TA=25℃, humidity<75%, unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on our corporate standards.
5. The performance in the datasheet is just fit for the part number in the selection guide, and may be different from the customer-designed product,
you can get more details from MORNSUN FAE.
6. Contact us for your specific requirement.
7. Specifications subject to change without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
A_S-2W & B_S-2W B/1-2012