TC100PW-EX Datasheet, PDF (4/4 Pages) MORNSUN Science& Technology Ltd. – PROGRAMMABLE THERMOCOUPIES ISOLATION SAFETY BARRIER
Hazardous
Area
6
mV
Channel 1
5
TC600PW-EX TC640PW-EX TC602PW-EX
Safe
Area
8
Channel 1
7
10
Channel 2
9
+ RL
4~ 20m A
-
+ RL
4~ 20m A
-
O utput
O utput
channel 1 channel 1
RL
+
+
+
Vo1 RL
4~ 20m A Ue
-
-
-
Output
Output
channel 2 channel 2
RL
+
+
+
Vo2 RL
4~ 20m A Ue
-
-
-
11 12
Power
C urrent source
output
Voltage source
output
Loop supply pow eroutput
INSTALLATION & DISASSEMBLY
Installation
DIN35mm standard rail installation:
1.Insert the top of the instrument card in the rail;
2.Push the bottom of the instrument into the rail.
Disassembly
1. Insert a screwdriver between the bottom of the card lock and the rail;
2. Pull up the screwdriver and press the card lock downwards;
3. Pull the instrument out of the rail.
1
2
PACKAGING DIMENSION & PACKAGING DIAGRAM
3
1
2
Note:
1. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
2. In this datasheet, all the test setup and methods are based on our corporate standards.
3. All characteristics are meant for listed model, non-standard models may perform differently, you can contact MORNSUN FAE for more details.
4. Contact us for your specific requirement.
5. Specifications are subject to change without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: info@mornsun.cn
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
TCxxxPW-EX 2013.11.01-A/0 Page 4 of 4